Form P7681 Edition 2
4
SPECIFICATIONS
Tested to ISO8662-7
Tested in accordance with ISO 15744 (Pneumatic tools)
Measurement uncertainty of the Sound Pressure Level ‘Kpa’ = 3dB(A)
Measurement uncertainty of the Sound Power Level ‘Kwa’ = 3dB(A)
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and the parts be separated by material so that they can be recycled.
Model
Handle
Drive
Impacts / min.
Inlet Connection
(
Thread
)
Minimum Inside Ø
(
Air Hose
)
I.D.
Type
in
2
bpm
NPT
in. (mm)
2130XP
pistol
1/2”
1,200
1/4
3/8 (10)
2130XP-2
pistol
1/2” Extended
Anvil
1,200
1/4
3/8 (10)
Model
Recommended
Torque Range
Impacting Sound
Level dB (A)
Free Speed Sound
Level dB (A)
Vibrations
Level
I.D.
Forward
ft•lbs (N•m)
Reverse
ft•lbs (N•m)
Pressure
(
Lp
)
Power
(
Lp
)
Pressure
(
Lp
)
Power
(
Lp
)
m/s
2
2130XP
25 to 350
(34 to 474)
602 max.
(816 max.)
94.3
105.3
90.8
101.8
4.6
2130XP-2
25 to 350
(34 to 474)
602 max.
(816 max.)
94.3
105.3
90.8
101.8
4.6
SOURCE/DATE CODE
LOCATION
(Dwg. TPD188)