Trouble
Probable Cause
Solution
Sluggish operation
Dirt or oil gum accumulation on internal parts
In a well ventilated area, pour 3 cc of a clean, suitable,
cleaning solution into the air inlet and operate for 30
seconds. After flushing, lubricate with the recommended
oil.
Loss of power
Worn Valve
Replace the Valve.
Loss of efficiency
Worn Piston and/or accessory
Replace worn parts.
Related Documentation
For additional information refer to:
Product Safety Information Manual 04581450.
Product Information Manual 03528072.
Parts Information Manual 16605875.