20
This page may be photocopied and used by inspectors or maintenance personnel.
INSPECTION AND MAINTENANCE REPORT
Ingersoll-Rand Electric Winches
Model Number:
Date:
Serial Number:
Inspected by:
Reason for Inspection: (Check Applicable Box)
1. Scheduled Periodic Inspeciton
( ____ Quartely ____ Semiannually ____ Yearly)
Operating Environment:
2. Discrepancy(s) noted during Frequent Inspection
3. Discrepancy(s) noted during maintenance
Normal ___ Heavy ___ Severe ___
4. Other: ____________________________
Refer to the Parts, Operation and Maintenance Manual "INSPECTION" section for general inspection criteria. Also refer to appropriate
National Standards and Codes of practice. If in doubt about an existing condition contact the nearest Ingersoll-Rand Distributor or the
factory for technical assistance.
COMPONENT
CONDITION
CORRECTIVE
ACTION
NOTES
Pass
Fail
Repair
Replace
Base and Support
Frames
Motor Brake
(125% Load Test)
Motor Brake
(Visual Inspection)
Electric Motor
Controls
Electrical System
Fasteners
Reducer Assembly
Labels and Tags
- - -
Chain and Sprockets
Shafts
Wire Rope Anchor
Wedge
- - -
Guards
Torque Limiter
(optional feature)
Limit Switch
(optional feature)
Other Components
(list in NOTES
section)
TESTING
Pass
Fail
NOTES
Operational (No Load)
Operational (10% Load)
Operational (Maximum Test Load *)
* Maximum test load is 125% of rated line pull.
Summary of Contents for 10000B20
Page 13: ...12 DRUM SWITCH CONNECTION DIAGRAMS Dwg MHP0201...
Page 14: ...13 230 Volt Single Phase 60 Hz Dwg MHP0271 WIRING DIAGRAM...
Page 15: ...14 WIRING DIAGRAMS Dwg MHP1086...
Page 16: ...15 Dwg MHP1087 WIRING DIAGRAM 208 575 Volt Three Phase 50 or 60 Hz 22 Amp and smaller...
Page 17: ...16 WIRING DIAGRAM Dwg MHP1088 208 575 Volt Three Phase 50 or 60 Hz 22 Amp and larger...