6.6.2
Remote Key Injection (PKMS) Initialisation
This function allows the Paymark security keys to be injected into the terminal
through the following steps below.
Step Terminal Display
Description
1.0
NITRO
Press FUNC.
2.0
FUNCTION?
Key in 87 and press ENTER
3.0
RKI PASSWORD?
Key in 6987 and press ENTER
4.0
REMOTE INIT
IN PROGRESS
Terminal starts to download remote keys into the terminal from the Paymark host.
5.0
PROCESSING NOW
Terminal has begun to download the keys into the terminal.
6.0
ACCEPTED
RKI logon was successful to download the keys to the terminal.
After a successful RKI (PKMS) key injection into the terminal, reseller will then
need to contact Paymark Key Assist helpline on 0800 653 875 to get the keys
released against the terminal ID. A merchant logon can then been initiated
and successfully completed with an ACCEPTED response, the terminal is ready
to process transaction.