![Ingenico iWL252 Operating Manual Download Page 64](http://html.mh-extra.com/html/ingenico/iwl252/iwl252_operating-manual_2058835064.webp)
SKYZER TECHNOLOGIES
PAGE 64 OF 116
NITRO INGENICO ICT250 AND IWL252 2015 PAYMARK SOFTWARE OPERATING GUIDE
Version 1.0
6.6 REMOTE KEY INJECTION (PKMS)
The Ingenico terminal supports Remote Key Injection technology to enable
automated injection of security keys from Paymark.
6.6.1
Remote Key Injection (PKMS) Configuration
This function is used to configure the Remote Key Injection operation and can
be performed through Dial-up, TCP-IP (Broadband) and GPRS mode.
6.6.1.1 Dial-up RKI Configuration
Step Terminal Display
Description
1.0
NITRO
Press FUNC
2.0
FUNCTION?
Enter 7418, press ENTER
3.0
SELECT OPTION
1. RKI CONFIG
2. ENABLE CTL
3. ENABLE RCPT HDR
4. ENABLE MERC
RCPT
Select option 1 for RKI configuration by pressing the corresponding number key
4.0
RKI CONFIG?
ENTER OR CLEAR
Press ENTER to proceed with the RKI configuration or CLEAR to cancel and exit to
idle screen
5.0
NII?
018
This parameter specifies the Network International Identifier that the terminal uses
to route messages to Paymark.
Press ENTER.
6.0
RKI PHONE NO?
08797
This parameter specifies the Phone number of the Paymark Host, where it will be
connecting to download the keys. By default, the RKI phone number is set as
08797.
NOTE: If the merchant has the Toll Bar on the site, then key in this phone
number 1797 to obtain connectivity to Paymark network.