TITAN GO Product Manual |
Wiring and Connections
INGENIA | 2022-07-14 08:35:14
71
Example of resolver signals
Next table shows the resolver electrical specifications.
Specification
Value
Type of inputs
Non-isolated. Differential. ESD protected
ESD capability
IEC 61000-4-2 (ESD) ± 15 kV (air), ± 8 kV (contact)
Number of inputs
2 (SIN and COS)
Number of outputs
1 (EXC)
Excitation signal voltage
10.8 V
pp
(7.6 V
AC
) *
Excitation frequency
10 kHz *
Transform ratio
1:0.5 *
*These values can be adjusted to the customer needs on demand. Please, notify the desired resolver specifications
when ordering a Titan Go.
The following picture shows how to connect the resolver to the Titan Go servo Drive: