![Infranor XtrapulsCD1-pm Installation Manual Download Page 7](http://html.mh-extra.com/html/infranor/xtrapulscd1-pm/xtrapulscd1-pm_installation-manual_2058370007.webp)
7
XtrapulsCD1-pm
– Installation manual
Chapter 1 - General description
The very small dimensions of the XtrapulsCD1-pm positioner allow an optimum integration in 300 mm deep
cabinets (connectors included). The XtrapulsCD1-pm positioner operates with a PROFIBUS DP interface or in
stand-alone by using only digital I/Os. The selection of the various operation modes (PROFIBUS or stand-alone)
is made by means of micro-switches accessible by the operator.
2.2 - REFERENCE TO THE STANDARDS: "CE" CERTIFICATION
Series XtrapulsCD1-pm positioners have been approved with regard to their conformity with the Electromagnetic
Compatibility standards concerning the power servos referenced in the EN 61800-3 standard "Electrical variable
speed power servo systems":
- EN 55011, group 1, C3 category, regarding radiated radioelectric disturbances,
- EN 61000.4-2-3-4-5 regarding immunity.
Standard to be applied to the electrical equipment of industrial machines: EN 60204-1.
2.3 - REFERENCE TO THE STANDARDS: "UL" LISTING
Xtrapuls CD1-
pm series have been “
C
UL
US
” listed according to UL508C, and UL840 regarding the insulator.
This product was evaluated to:
-
the Third Edition of UL508C, the UL Standard for Power Conversion Equipment, for the UL Listing (USL),
-
the CSA Standard for Industrial Control Equipment, C22.2 N° 14-10, for the Canadian UL Listing (CNL).
Providing that the manual is specifying that the end user has to provide an isolated power supply, for 24 VDC
auxiliary input protected by a 4 A UL Listed fuse, the power board is considered within a limited voltage/current
circuit per section 31.4 of UL508C. Therefore, spacings on the power board are not required to be evaluated per
section 31.2 of UL508C and were evaluated according to UL 840.
Per UL 840 requirements, spacings are limited to 2.5 mm assuming pollution degree 2 environment.
Ground connection is fixed in the frame of the device by a rivet, Avibulb masse, BN10-5168. The connector
complies with standard dimensions given in table 6.2 of UL 310, the standard for Electrical Quick connect
terminals.
3 - OTHER DOCUMENTS REQUIRED FOR THE COMMISSIONING
" XtrapulsCD1-pm Profibus positioner User Manual".
" XtrapulsCD1-pm Profibus Communication Profile".
"CD1-pm SinCos track feedback" application note regarding the use of motors equipped with "SinCos tracks"
position sensors.
"CD1-pm absolute encoders feedback" application note regarding the use of absolute single-turn, multi-turn
or linear encoders using the ENDAT or HIPERFACE Communication protocols.