![Infranor SMT-BD2/m Manual Download Page 44](http://html.mh-extra.com/html/infranor/smt-bd2-m/smt-bd2-m_manual_2058381044.webp)
44
CHAPTER 7 – Programmation
SMT-BD2/m
3.
4
-
MANUAL
MODE
PARAMETERS
There are 2 types of manual motion:
- manual positioning: moving of the motor until a given position via the serial link.
- manual jog: continuous movement when the JOG signal is activated.
(JOG+ for a movement in the positive direction and JOG- for a movement in the negative direction)
The motion profile parameters are:
- motion speed,
- acceleration time,
- deceleration time.
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed
parameter value. When the
motion speed
is lower than the maximum speed, the trajectory acceleration and
deceleration times are proportionally reduced.
Remark : The JOG deceleration time parameter value is also used when the STOP input is activated.
Maximum speed
Acceleration time
Deceleration time
Motion speed