CHAPTER 6 – Commissioning
SMT-BD2/m
CHAPTER 6 - COMMISSIONING
1 - CHECKING THE AMPLIFIER CONFIGURATION
1.1
-
S
TANDARD AMPLIFIER CONFIGURATION
The standard SMT-BD2/m amplifier configuration is given below.
See chapter 5, section 1 "Hardware
adjustments" for the jumpers location
*
Inputs 0 V reference jumper I/O is open (optoisolated inputs)
*
Current loops adjustment jumpers in B2 position (medium gain)
*
Motor temperature sensor jumper in MN position (PTC sensor type)
*
Undervolt fault inhibition jumper in JK position ("Undervolt." fault enabled)
*
Serial link communication jumper in B position (RS-232 protocol)
*
Drive address selection jumpers in OFF position (address 0 selected)
*
Encoder signal jumpers COD in B1 position (TTL incremental encoder configuration)
*
Encoder marker pulse jumper in ZM position (encoder marker pulse enabled)
*
Commutation signal jumpers COM in B3 position (incremental encoder configuration without HES)
1.
2
-
E
NCODER CONFIGURATION
If the motor is equipped with a "TTL incremental encoder", select the following COD and COM jumpers setting.
If the motor is equipped with a "Sin/Cos incremental encoder", select the following COD and COM jumpers
setting.
If the motor is equipped with an "Absolute single turn Sin/Cos encoder" (Heidenhain ERN 1085 or compatible),
select the following COD and COM jumpers setting.
COM
COD
B2
B1
B5
B4
B3
During the machine adjustments, some drive connection or parameter setting errors may involve
dangerous axis movements. It is the user's responsibility to take all necessary steps in order to
reduce the risk due to uncontrolled axis movements during the operator's presence in the concerned
area.
!