![Infotrend EonStor DS B Series Hardware Manual Download Page 72](http://html.mh-extra.com/html/infotrend/eonstor-ds-b-series/eonstor-ds-b-series_hardware-manual_2058315072.webp)
EonStor DS B12/B24 Series
RAID
configuration
Remote replication functionality is not supported
using this configuration. For remote replication
setup, please refer to “
SAN with Port Trunk (Remote Replication Enabled)
”.
4 logical drives (each has 4 member drives; for better
performance, you can include drives from JBOD)
LD0 mapped to CH0 AID and CH0 BID; LD assigned to
controller A
LD1 mapped to CH1 AID and CH1 BID; LD assigned to
controller A
LD2 mapped to CH2 AID and CH2 BID; LD assigned to
controller B
LD3 mapped to CH3 AID and CH3 BID; LD assigned to
controller B
*
LD assignment
NOTE
In the event of single controller failure, a logical drive is accessed through the
host IDs managed by the alternate RAID controller. Host IDs and port IPs do
not fail-over to the surviving controller. Therefore, the EonPath multi-pathing
driver is necessary for path redundancy and controller failover.
72