WM-112
Serial to Ethernet Module
Copyright © 2007, Infosystem Technology Corporation, Ltd.
26.
WM-112
Serial to Ethernet Module
Configuration
C. By Direct Broadcast Commands
User Level:
For General Users
Admin Level:
For Factory Default Setting
– Command List B – User Level –
Command Description Notes
Purpose
Set the parameters of WM-112
Syntax
S <MAC>/<IP>/<Password>/<Parameter>/<Value>
A for accept
Return
C for cancel
Send
S
0.128.200.255.251.242/192.168.1.1/123/IP/192.168.1.2
S
Example
Back
A or C
Purpose
Reboot WM-112
Syntax
R <MAC>/<IP>/<Setup Password>
AR for accept
Return
CR for cancel
Send
R 0.128.200.255.251.242/192.168.1.1/123
R
Example
Back
AR or CR