2.2.2 LED INDICATIONS
Q7 CPU board LED indications
Refdes
Function
D2
VPH
D3
Battery Chanrging
D4
Battery Chanrging
Carrier board LED indications
Refdes
Function
D505
Notification LED
D506
S4 Power rail
D509
CPU Reset out
D500
Privacy LED
D527
ATX 5V STBY indicator
D528
DC Jack power indicator
D513
PCIe hub INT
D511
PCIe Lanegood-0: Uplink to CPU
D508
PCIe Lanegood-1: ETH controller
D510
PCIe Lanegood-2: mini PCIe
D512
PCIe Lanegood-3: x1 PCIe connector
D514
PCIe hub error
D521
SATA uplink to CPU
D522
SATA port A
D524
SATA port B
2.3 JUMPER SETTINGS
ATX power ON
This option is provided for enabling the ATX main rails without GPIO signal.
Mount jumper shunt on header P513 for enable
V3P3_JACK feeder
This is for feeding V3P3_ATX from V3P3_JACK. This will help to operate minimal level 3.3V devices
without ATX power supply. On detecting ATX presence this will get disabled.
Mount P517 for V3P3_JACK feed
LVDS Voltage Selection
Voltage for the LVDS connector can be selected either 12V or 5V by placing the jumper shunt as shown
in the table below.
Voltage
Description
12V
P510 (Pin 1-2)
5V