INSIGHT DLP
SENSOR 0610S Appliance Hardware Installation Guide
www.infolocktech.com
9. REAR PANEL CONNECTIONS
(continued)
NOTE:
The server offers redundant, hot-swap capability. The
connections to AC mains should be made in a manner appropriate
to local code and consistent with customer power distribution with
or without redundant sources.
CAUTION
The power supply is hot-swappable only when you have a server
with redundant power supplies installed. If you only have one
power supply installed, before removing or replacing the power
supply, you must first take the server out of service, turn off all
peripheral devices connected to the server, turn off the server by
pressing the power button, and unplug the AC power cord from
the server or wall outlet.
Step 1
Connect the Ethernet cables for MGMT, DLP,
and SPAN (if required).
Step 2
Connect any other required cables.
Step 3
Connect the power cords.
Proceed to
Section 10, Front Panel Operation
on page 13.
POWER SUPPLY CONDITION
Output ON and OK
No AC power to both power supplies
AC present / Only 5VSB on (PS off)
AC cord unplugged or AC power lost; with
a second power supply in parallel still with AC
input power
Power supply warning events where the
power supply continues to operate; high
temp, high power, high current, slow fan
Power supply critical event causing a
shutdown; failure, OCP, OVP, fan fail
LED STATE
GREEN
OFF
AMBER
OFF
1Hz Blinking
AMBER
AMBER
In normal operation the Power Good LED on Power Supply Module 1
and Module 2 will be SOLID GREEN. If the power is down, both LEDs
will BLINK GREEN.
Power Supply Status LED
There is a single bi-color Power Good LED on each power
supply module to indicate power supply status. The LED
operation is defined in the table below.