14/22
Method 1:
Use the CH SELECT buttons on the front panel of the Encoder/
Decoder.
Accoding to the methods metioned in Chapter 5, set the ID of Encoder, then
set the ID of Decoder, finally set the Encoder ID from which to subscribe the
stream. Match all Encoders and Decoders in the same way.
Method 2:
Use the RS-232 serial port command control.
Connect the RS-232 port of Encoder/Decoder to a PC or control system, as
shown in the figure below. Then use a Serial Command tool on PC to send
the RS-
232 command code: “!OUT xxx FR yyy\r\n”. The function of this
command is to connect the Decoder (ID:xxx) to the Encoder (ID:yyy). Match
all Encoders and Decoders in the same way.
TX
Grou nd
RX
3-pin Phoenix Connector
RS-232
RS-232 to USB cable
PC
Method 3:
Use the IR remote control (optional).
The IR of Decoder supports using IR remote control. The button number on
the IR remote control is the ID of Encoder which is to be connected to the
current Decoder. You can select Encoder 1~40 to match the current Decoder
by directly pressing button 1~40. If you press and hold the button 1 for 5
seconds, Encoder 41~80 can be selected.
IR remo te con trol