InfluxGreen Energy Pte Ltd
Model:
IGSI-3 Phase Output Ser ies
Rev. 0
16
2.6.1 Assembl e the DC con n ect or
2.6.1.1
Strip the cable 6-8mm,then connect the bare wire core into the core tube of
connector.
2.6.1.2
Crimp the contact barrel by using a hex crimping die. Put the contact barrel with the
stripped cable in the corresponding crimping notch and crimp the contact.
2.6.1.3
Insert the core tube into the slot of the connection until you hear the locking sound,
indicating in connection is in place.
2.6.1.4 Insert contact cable assembly into back of the male and female connector. Tighted
the nuts accordingly towards the opposite direction. The assembly is complete.
5
WARNING
: Shock hazard! Before removing the panel, disconnect the inverter at both the AC
and DC side and allow at least 5 minutes for the internal capacitors to discharge.