1  

Chapter I Precautions 

 
The IP domes have been designed and manufactured to ensure 
maximum reliability for various applications. However, the actual 
performance may also depend on how you plan and make the 
installation. Before attempting to install or operate the IP domes, 
therefore, please thoroughly familiarize yourself with the following 
instructions, and make sure that they are strictly followed. 
 

1.1 Be Careful During Transportation 

To avoid damage, protect the units against extremes of pressure, 
shock or vibration during transportation. The products must be 
shipped in parts disassembled as the original packing did, and kept 
away from water, fire and high magnetic radiation. In no event will 
Infinova be liable for any damage or loss arising from improper 
transportation or storage. 
 

1.2 Plan Your Installation Beforehand 

z

 

Do not install an indoor dome in outdoor environment. 

z

 

Keep the domes away from electric or magnetic fields. Devices 
such as TV, audio speaker, high-capacity transformer, electric 
motor and radio transmitter usually generate magnetic fields that 
may distort the camera images. 

z

 

Protect the domes from dampness and dust. Do not install the 
domes where the humidity is over 90%, or where there is greasy 
smoke, steam, or too much dust. 

z

 

Avoid installations in a hostile environment. The domes are 
designed to work at a temperature ranging from -10

o

C to +60

o

C  

(indoor) or -40

 

 to +60

 

 (outdoor). 

 

1.3 Pay Extra Care During Installation 

z

 

Handle the unit carefully, and do not drop or subject it to strong 
shock or vibration. 

z

 

Always use proper safety equipment for the location and 
installation. 

z

 

Make sure that the materials are capable of supporting four times 
the maximum specified load. 

z

 

The unit contains electrostatic-sensitive components. Be careful 
not to touch any exposed circuits directly when connecting wires 
and assembling the domes. It is recommended to use proper 
static-proof equipment when handling the PCB. 

z

 

Make sure that the domes are powered off when connecting wires 
to avoid accident during installation. 

z

 

Do not directly touch the lower dome bubble. The dome bubble 
is a precision component, and any scratch could result in a 
degradation of image quality. 

z

 

Make sure that no metal objects or flammable substance 
accidentally get inside the domes to avoid damage caused by 
short circuit or fire. 

 
 

1.4 Take Necessary Cautions for Electrical Safety 

 

z

 

Always conform to local electrical safety codes when installing 
or operating the domes. 

z

 

When powering the domes and the auxiliary devices connected, 
check that the power supply specifications correspond to those 
required.  

z

 

Keep the domes and communication cables at least 165 ft. (50 m) 
away from high voltage equipment or cables. If a particular 
installation requires closer wiring, shield the communication 
wires with steel tube, and make it properly grounded. 

z

 

In certain circumstances, the following measures are necessary 
for electrical safety: 

z

 

When making outdoor installation, route cables under eaves 
whenever possible. 

z

 

Do not use trolley wire in open area. Instead, place cables in steel 
tubes that are properly shielded underground. 

z

 

Be sure to install extra strong lightning proof equipment where 
strong thunderstorms are frequent or where there is a high faradic 
facility (e.g., a high voltage transformer substation) nearby. 

 

1.5 Ensure Proper Operation and Maintenance 

 

z

 

Protect the domes from excessive light. Do not point the domes 
directly at such extremely bright light sources as the sun. 
Otherwise, the CCD might be permanently damaged. 

z

 

Do not dissemble the dome drive module. There are no user 
serviceable parts inside the module, and failure to observe this 
instruction will cause loss of warranty. For internal settings and 
repairs, please refer to authorized personnel only. 

z

 

The dome bubble should be cleaned periodically to get clear and 
crisp images. Clean the dome bubble with a soft cloth, and be 
careful to hold its edge only. Do not directly touch the dome 
bubble. Any finger marks or scratches on the cover might cause 
vague or distorted images. 

z

 

Do not use chemical products like benzine or thinner. If neutral 
cleanser is required, make sure to read all accompanying 
instructions to determine that no negative effect will be caused. 

z

 

Prevent any plastic or rubber material from staying in contact 
with the cabinet for a long period of time. Otherwise, it might 
cause paint peeling or damages.

 

 

Summary of Contents for V1700N-NE2 Series

Page 1: ...ting Ceiling Mounting indoor outdoor indoor outdoor This manual addresses the installation procedures of Infinova V1700N NE2 series IP domes The domes feature an all in one design and compact structur...

Page 2: ......

Page 3: ...arning The IP domes comply with the FCC rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received...

Page 4: ...all service matters to qualified personnel z Save product packaging to ensure availability of proper shipping containers for future transportation z The power should be subject to below conditions ex...

Page 5: ...ing 5 3 3 Wall Mounting 6 3 3 1 Specifications for Short Arm Wall mounting 6 3 3 2 Specifications for Long Arm Wall Mounting 6 3 3 3 Installation Procedures for Wall Mounting 6 3 4 Corner Mounting 7 3...

Page 6: ......

Page 7: ...bble is a precision component and any scratch could result in a degradation of image quality z Make sure that no metal objects or flammable substance accidentally get inside the domes to avoid damage...

Page 8: ...ively according to the labels on the cable The video cable use coax cable and shielded twisted paired cable for the control cable Video coaxial cable The video coaxial cable must meet the requirements...

Page 9: ...ge For indoor mounting take off the two flexible buckles from upper housing and then pull the upper housing with screw rod through the circle in the ceiling After that put the flexible buckles onto th...

Page 10: ...roof Mounting 3 2 1 Over roof Mounting Specifications The over roof mounting includes plane installation and sidewall installation Below figure demonstrates the dome and brackets specifications Unit m...

Page 11: ...commended to apply thread compound to the threads on the housing Secure the connection with a holding screw Sidewall Mounting Horizontal Surface Mounting Figure 3 10 Installing Housing 4 Take out the...

Page 12: ...ns for long arm wall mounting Unit mm Indoor Mounting Figure 3 14 Indoor Long Arm Wall Mounting Outdoor Mounting Figure 3 15 Outdoor Long Arm Wall Mounting 3 3 3 Installation Procedures for Wall Mount...

Page 13: ...y cord As one end of safety cord has already fixed to the upper housing and the other end should be tied to the dome bubble Line up the screw holes of the dome bubble with corresponding holes on the h...

Page 14: ...baud rate can be set via either software or DIP switch If setup via DIP switch is selected please refer to Appendix I 6 Line up the two tabs located on the upper side of the dome drive with the corre...

Page 15: ...Holding Screw Indoor mounting Figure 3 29 Installing Housing 5 Take out the dome drive from the dome package Note dimisters are included in outdoor dome drive The address ID and baud rate can be set...

Page 16: ...and secure it with expansion bolts For dimensional diagram of the pendant mount base please refer to the following figure 85 4 Through hole Evenly distributing 6 5 Bottom 90 9 Indoor mounting 120 3 6...

Page 17: ...cover with supplied screws 8 Turn on the power The dome will pan tilt and zoom to initiate system parameters as well as to verify the normal operation of the dome drive After the initiation sequence t...

Page 18: ...12 1 Setting Camera ID...

Page 19: ...13...

Page 20: ...X X X ON X OFF Appendix II Assembly and Disassembly Procedures Assembly Procedures Line up the two tabs located on the upper side of the dome drive with the corresponding grooves in the housing Inser...

Page 21: ...commended to wrap the threaded part of housing assembly with waterproof tape to prevent water inleakage which may lead to failure of internal circuit Installation of waterproof tape is shown below 1 T...

Page 22: ...ter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94...

Page 23: ...rhead wiring is prohibited because it s more likely to encounter lightning strike Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the...

Page 24: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V1 1 1207...

Reviews: