10
Click “OK” button, the system will skip to login interface
automatically.
1HWZRUN/LQN
Figure 4-18
In this interface
ˈ
user can choose the Network Link modes. There
are five modes are available:
˄
1
˅
10M-half
˄
2
˅
10M-full
˄
3
˅
100M-half
˄
4
˅
100M-full
˄
5
˅
Auto
1RWH
Only the super user can set this option.
)73VHWWLQJV
Figure 4-19
V1492N-N series IP PTZ camera has the function of alarm
associated with FTP upload.
Configure server IP, user name and password in the FTP settings
and enable FTP alarm in alarm settings, then alarm associate with
FTP upload can be achieved.
60736HWWLQJV
Figure 4-20
z
Server IP: Set mail server address.
z
From: Set sender’s mail address.
z
To: Mail address of recipient.
z
CC: Mail address of the person copy to.
z
Authentication: Enable or disable authentication function. This
function should be set according to authentication requirements
of mail server.
z
User name: Sender’s name, it can be set according user’s needs.
z
Password: Set sender’s password.
z
Note: there is no limit for Sender’s name and password settings.
After setting completes, click “Set” button to take effect.
If user selects “mail” in “Alarm Settings” interface, system will
send mail according to SMTP settings.
61036HWWLQJV
V1492N-N Integrated High-speed IP PTZ Camera has the heartbeat
function.
In the SNMP Settings interface, start the heartbeat server, set its IP
address and the heartbeat interval, and then heartbeat package will
be sent to the appointed server or the client at the specified interval
so that the server or client can easily know about the network status
of the camera.
4.5 Time Settings
Click
button in the navigation bar to display the
following Time Zone Settings interface:
Figure 4-21
7LPH] RQH
Select the desired time zone in the scroll box, and then click
“Set” to save it.
There are 33 time zones for selection: GMT-12:00~GMT~GMT+13:00, and
the default setting is GMT Greenwich Mean Time.
For Daylight Saving Time enable region, please tick “Automatically adjust
clock for daylight saving changes”.
6\QFKURQL]HZ LWKFR PSXWHUWL PH
used to check whether the time of
system is the same as that of local PC. Click “Set” to adjust.
6\QFKURQL]HZLWK173VHUYHU
whether to select NTP server or not. Select
“NTP” to enable NTP server, or otherwise disable NTP server.
If NTP server is selected, you can input NTP server address into IP bar.
Click “Set” to finish. If so, the system will adjust time with NTP server
automatically.
4.6 Alarm settings
Click
button in the navigation bar to display the
following Alarm Settings interface:
Summary of Contents for V1492N-18N05
Page 2: ......
Page 6: ......
Page 40: ...Infinova 6WRXWV DQH 0RQPRXWK XQFWLRQ 1 8 6 7HO 86 RQO D VDOHV LQILQRYD FRP V1 4 1208...