12
EN
Pleats
3-Terminals and connectors of the video door entry system
The following terminals and connectors are located on the back of the PLEATS video door entry system.
-8-pole clamp:
24VDC+: Positive 24V auxiliary power supply.
24VDC-: Negative 24V auxiliary power supply.
M: Common mass.
CH: 12-24V AC-DC relay contact (The two terminals marked CH are a normally open contact).
FP: Auxiliary "landing call" button.
AL: "Generic alarm" auxiliary button.
P: "Panic" auxiliary button.
- Ethernet connector:
Connector used for data traffic and POE power supply.
- RJ11 connector
Connector used to connect the handset.
4-Maintenance
Clean the product using a soft cloth, do not pour water on the device and do not use any type of chemical product.
Terminals and connectors
Ethernet connector
8-pole clamp
RJ11 connector