Introduction to Digital Power Conversion
XMC4000/1000 Family
Control Loops
Application Guide
82
V1.0, 2015-01
FADC PCC Slope Compensation Circuit; Clarification Example
This circuit is a downsized version of the corresponding ACMP example in
. The RC-
network accomplishes external linear control of a slope compensation voltage ramp.
Figure 66
ACMP PCC Slope Compensation Clarification
CCU 4 Blanking Control
There is a CCU 4 blanking control, to reject noise from power switch commutations, proposed by
using the Gate functionality of the VADC input channel.
Note:
An alternative would be to use the corresponding function in the ACMP example in
intead.
Current Measurement Signal
The output voltage of the Current Measurement is assumed to be representing the inductor current.
See section