![Infineon XENSIV BGT60TR13C User Manual Download Page 31](http://html.mh-extra.com/html/infineon/xensiv-bgt60tr13c/xensiv-bgt60tr13c_user-manual_2055086031.webp)
31 of 59
2022-23-05
User Guide for XENSIV™ K
IT CSK BGT60TR13C
Table of contents
•
The maximum range parameter can be set up to 10 m. However, verification testing has been done
primarily for a maximum range of 5 m.
•
The detection range might reduce at angles depending on the sensitivity setting being used. For
example, with the default settings using medium sensitivity at [+45 degrees, -45 degrees], macro-
movement detection range might reduce to 4 to 4.5 m, whereas micro-movement detection range
might reduce to 3.5 to 4.0 m. Higher-sensitivity settings help in achieving longer ranges at angles.
•
Elimination of target detection through the wall is not supported in this release.
•
The solution is not designed/optimized for presence detection through glass walls.
5.8
Recommendations
•
It is recommended to set the maximum range parameter based on the room size. The user should
avoid setting longer ranges for smaller rooms (e.g., 5 m maximum range for a room length of 3 m), as
it might result in false presence detection caused by multiple reflections.
•
The solution might react to certain moving conditions (e.g., moving curtains, plant movements,
facing a wall within its active zone, etc.) so, for the time being, the user is recommended to either
install it in a location where such conditions can be avoided, or adapt the maximum range
accordingly.
•
For optimal results, the user is recommended not to install a reference HW board in corners where
the radar chip is facing a side wall, to avoid multiple reflections.