18 of 59
2022-23-05
User Guide for XENSIV™ K
IT CSK BGT60TR13C
Table of contents
application is selected, the attributes will be pushed to the device and the device will reboot to the desired
application.
Note: The selection of a new application may temporarily cause the connectivity to disconnect and reconnect
from the Rapid IoT connect cloud platform.
Please refer Appendix for detailed list of attributes with their definition and possible values.
Table 2
Attributes for Presence application
Table 3
Attributes for Entrance Counter application
Attribute
Description
radar_presence_range_max
0.0
–
10.0
Maximum detectable range for presence, in meters.
Default value is 2 m.
radar_presence_sensitivity
0.0
–
1.0
Sensitivity for presence detection. Step of 0.1.
Default value is 0.5.
kit_mask_level
Disable logs, enable minimal logs or full logs to cloud
60
: WARN, MINOR, MAJOR, FATAL all to UART terminal
62
: INFO, WARN, MINOR, MAJOR, FATAL all to UART
terminal
124
: WARN, MINOR, MAJOR, FATAL all to Cloud UI as
well as UART terminal
Attribute
Description
radar_counter_installation
side
: side mounting installation
ceiling
: ceiling mount installation
Default is side.
radar_counter_orientation
portrait:
radar board is installed at portrait orientation
landscape:
radar is installed at landscape orientation
Default is portrait.
radar_counter_entrance_width
0.0
–
3.0
Entrance width in meters. Default is 1.0.
radar_counter_ceiling_height
1.0
–
3.0
Ceiling height in meters. This parameter is used in ceiling
mount installation. Default is 1.0.
radar_counter_min_person_height
0.0
–
2.0
Minimum person height to count, in meters. This
parameter is used in ceiling mount installation. Default is
1.0.
radar_counter_traffic_light_zone
0.0
–
1.0
Area where traffic light is red, in meters. This can be used
for remiding social distancing purpose. Default is 1.0.
radar_counter_sensitivity
0.0
–
1.0