XDPL8218 design guide
For high power factor flyback converter with constant voltage output
Parameter configuration list, set-up and procedures
17.3
Parameter configuration procedures
After the hardware connections for XDPL8218 configuration (see
) are done, please start the program
by clicking the shortcut “.dp Vision” on the desktop.
Note:
During the program start-up, if the system shows there is a newer version of .dp Vision, please follow
the procedure and update accordingly. As the screenshots were taken based on .dp Vision version
2.0.9.1, it might look different for newer versions of .dp Vision.
A .dp Vision user manual is available by clicking [Help] >> [Help contents], to provide the detailed instructions
on how to use this GUI for parameter configuration. Alternatively, the following simple guide is also available
for quick and easy reference.
Open the XDPL8218 parameter configuration file (*.csv) from the default installation folder of the project add-
on at C:\Users\<Username>\Infineon Technologies AG\.dp vision\Parameters, as shown in
Figure 23
Opening the XDPL8218 parameter configuration file (*.csv) in .dp Vision
After opening the parameter csv file, a list of configurable parameters with default values based on the
reference board design will be shown (see the box on the left in
). These default values can be
changed for another board design, by referring to the design guide from
Section 2
Section 15
and the fine-
tuning guide in
Section 18
If a parameter value is changed and no limit violation is found, the changed value itself will turn blue, like the
example in
Figure 24 in
which the R
cs
parameter in the hardware configuration section has been changed from
0.2 Ω to 0.18 Ω. Otherwise, if an error is detected (e.g. exceeded min./max. value), the parameter value which
caused the error will turn red and the message bar of .dp Vision (see the top right in
) will show an
error message. If any error is not resolved, the user is not allowed to configure the IC with the changed value.
Figure 24
Changing parameter values of XDPL8218 configuration file in .dp Vision
Note:
For safety and proper system functioning, it is important to ensure the hardware configuration
section parameter values are compatible with the actual system hardware dimensioning.
Select XDPL8218
configuration file to open
List of configurable parameters
Message Bar
Parameter value