TLE4997
User’s Manual
Configuration & Calibration Parameters
User’s Manual
23
v01_01, 2019-08
4.6
Clamping - CH, CL
The clamping function is useful for separating the output range into an operating range and error ranges. If the
magnetic field is exceeding the selected measurement range, the output voltage V
OUT
is limited to the clamping
values. Any value in the error range is interpreted as an error by the sensor counterpart.
shows an example in which the magnetic field range between B
min
and B
max
is mapped to voltages
between 0.8 V and 4.2 V.
Figure 4-3 Clamping Example
Clamping - TLE4997 :
The clamping values are calculated by:
Clamping low voltage :
(4.3)
Table 4-6
Clamping
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Clamping low
1)
1) If clamping is set it must be within the allowed output range.
V
CLL
0
–
99.98
%V
DD
Clamping high
V
CLH
0
–
99.98
%V
DD
Clamping quantization steps
ΔV
CLQ
–
1.22
–
%mV
at V
DD
= 5 V
Clamping voltage drift
ΔV
CL
-15
15
mV
in lifetime
2)
over temperature
2)
Valid in the range (5% of V
DD
) < V
OUT
<(95% of V
DD
) for T
J
≤
120°C
and (6% of V
DD
) < V
OUT
< ( 94% of V
DD
) for 120°C < T
J
≤
150°C
0
1
B
min
B
(mT)
B
max
V
out
(V)
5
2
4
3
Error range
Error range
Operating range
V
CLH
V
CLL
V
CLL
CL
4096
------------ V
DD
×
=