Aurix
™ Lite-Kit V1.1
Hardware Description
Board Users Manual
11
Revision June, 2020
3.1
Shield2Go and MikroBus
™ Pinout
The pin connectors for the Shield2Go Connectors 1 and 2 and the mikroBus
™ can be used to extend the
evaluation board or to perform measurements on the Aurix
™ TC275. Figure 5 shows the available signals at
these connectors. The pin table is also printed onto the top and bottom side of the Aurix
™ TC275 Lite-Kit.
Shield2Go Connector 1
Shield2Go Connector 2
Aurix™
Pins
Aurix™
Pins
1
+5V
5V
Aurix
Pins
1
+5V
5V
Aurix
Pins
2
AN16
AN1
RX
P33.8 10
2
AN18
AN1
RX
P20.3 10
3
AN17
AN2
TX
P33.9 11
3
AN19
AN2
TX
P20.0 11
4
P13.2
2)
SDA
RST/GPIO
2
P20.9 12
4
P13.2
2)
SDA
RST/GPIO2
P20.10
12
5
P13.1
2)
SCL
GPIO1
P32.2 13
5
13.1
2)
SCL
GPIO1
P32.3 13
6
GND
GND
CS
P11.2
14
6
GND
GND
CS
P11.10
14
7
VEXT
3V3
SCLK
P10.2
1)
15
7
VEXT
3V3
SLCK
P10.2
1)
15
8
P00.4
INT/GPIO3
MOSI
P10.3
1)
16
8
P10.8
INT/GPIO3
MOSI
P10.3
1)
16
9
P20.12 PWM/GPIO4
MISO
P10.1
1)
17
9
P20.13 PWM/GPIO4
MISO
P10.1
1)
17
mikroBus™ Connector
1
AN26
AN
PW
M
P2.8
16
2
P10.6
RST
INT
P10.7 15
3
P10.0
CS
RX
P15.1 14
4
P10.2
1)
SCK
TX
P15.0 13
5
P10.1
1)
MISO
SCL
P13.1
2)
12
6
P10.3
1)
MOSI
SDA
P13.2
2)
11
7
VEXT
3.3V
5V
+5V 10
8
GND
GND
GND
GND
9
Figure 5
Signal mapping of the pin headers for Microbus and Shield2Go Connector 1 and 2
Note:
1)
The SPI buses MOSI, MISO and SCK are shared on the Shield2GOs-, mikroBus™- and Arduino connectors.
2
)
The
I2C buses SCL and SDA are shared on the Shield2GOs, mikroBus™ and Arduino connectors and are additionally connected with analog Inputs AN24
and AN25. You can not use I2C and analog reading functions of AN24/AN25 simultanously.