11

SAFETY INSTRUCTIONS

Caution: When the device is not in use (storage, transport, end of charging, etc.) it is compulsory to 

disconnect the battery from the power cord.

Never carry the charger by the cord, and do not pull on the cord to disconnect it from the socket.

If a cord is defective or damaged, it must be replaced with a genuine set from the INFACO factory or 

from an approved INFACO dealer.

Never try to open the battery for any reason.

Never make any mechanical alterations to the battery, harness, charger or connectors.

Never let the battery or charger come into contact with water.

Never wear the battery on your back when it is charging.

Never expose the battery or the charger to high temperatures (direct sunlight, heating, etc.) > 60°C.

Never recharge the battery in temperatures below 0°C or above 40°C.

Do not charge the battery near infl ammable or explosive materials (fuel, gas, nitrogenated fertilisers, 

etc.).

Never leave to charge for extended periods without surveillance.

Never use chargers, batteries, cords, etc. other than those sold by INFACO. 

Do not use chemicals to clean the device (pruning shears, cords, batteries and charger).
To reduce health risks, INFACO recommends that persons with a pacemaker get medical advice and 

consult the pacemaker manufacturter before using this device.

When replacing a battery under warranty, the replacement will only be made on the condition that 
the capacity of the battery is less than 70% of its initial capacity.
However, we confi rm that the battery service life is at least fi ve seasons. If the battery does not last 
fi ve seasons, and if the equipment has been serviced, we will warranty on a pro-rata basis.
For example: Price of the new battery divided by 5 (service life) and multiplied by the number of 
seasons used.
The warranty will only be valid if the warranty card is fi lled out correctly and returned to the address 
featured on it. 
Should the warranty card not be returned immediately after the purchase of the device, the warranty 
start date will be the date the unit left the factory?

TERMS OF WARRANTY

Please remember that the INFACO Lithium charger (Ref.: 841C2/842C2) is for exclusive use with 
the F3015 Lithium batteries. It is not suitable for use with NiMH (Metal hydride) batteries.

Defective battery on channel 1:
Red LED on (not fl ashing)

1. Remove the battery from channel 1 and connect to 
channel 2.
2. If the problem persists, remove the defective battery from 
the charger and contact your approved INFACO dealer.

Defective battery on channel 2:
Red LED on (not fl ashing)

1. Remove the battery from channel 2 and connect it to 
channel 1.
2. If the problem persists, remove the defective battery from 
the charger and contact your approved INFACO dealer.

NOTMAL1B15_ENUSA_01.indd   11

NOTMAL1B15_ENUSA_01.indd   11

15/07/2020   10:40:55

15/07/2020   10:40:55

Summary of Contents for 831B

Page 1: ...USER S MANUAL MAL1b15 NOTMAL1B15_ENUSA_01 indd 1 NOTMAL1B15_ENUSA_01 indd 1 15 07 2020 10 40 12 15 07 2020 10 40 12...

Page 2: ...NOTMAL1B15_ENUSA_01 indd 2 NOTMAL1B15_ENUSA_01 indd 2 15 07 2020 10 40 12 15 07 2020 10 40 12...

Page 3: ...________________________________ 7 CHARGING THE BATTERY_____________________________________________8 Using the charger __________________________________________________________8 Charging the battery...

Page 4: ...rnings and instructions Failure to heed war nings and follow instructions may lead to an electric shock a fire and or serious injury ENVIRONMENTAL PROTECTION Follow all country specific waste disposal...

Page 5: ...Input 220 230V 50 60Hz 110 120V 50 60Hz Output 54 6V 2A Power 110W Fuse 3 15A These specifications are given as an indication only Under no circumstances may they be considered as contractually bindin...

Page 6: ...ACO Lithium charger Ref 841C1 841C2 It is prohibited to use a different charger as this may lead to a serious electrical accident Carrying the Equipment 1 Remove the battery the battery holder belt th...

Page 7: ...d place Keep the cord away from the cutting zone At the end of the pruning season remember to put the batteries in sleep winter mode to prevent their premature ageing during storage see page 11 We str...

Page 8: ...ly charge an 831B battery is about one and a half hours 2 Connect the other end of the power cord to the mains outlet 2 Once the battery is in place the charger detects it and begins charging Channel...

Page 9: ...r when not used for more than 1 month the following process must be applied this process can take up to 10 hours per battery Channel 2 4 Place the battery on channel 2 of the charger 5 If the battery...

Page 10: ...FACO dealer Do not store batteries when they are connected to the charger or to a tool Do not store the charger connected to the mains power supply All failures to follow the storage and safety instru...

Page 11: ...replacing a battery under warranty the replacement will only be made on the condition that the capacity of the battery is less than 70 of its initial capacity However we confirm that the battery servi...

Page 12: ...n we strongly recommend users of INFACO equipment to contact the dealer who sold them the equipment or our customer service department by dialling 33 0 5 63 33 91 49 To avoid all disputes please note...

Reviews: