27 - Inepro IP Reader (Konica Minolta)
These are the setting for the currently supported readers:
Wiegand:
Setting
Description
Value Description
Bits
Facility
code
Setting 1
Card ID. Because of the applied
interface it is possible that different
card readers are connected with this
communication protocol. To be able
to differentiate the different card type
the card type can be entered here.
-
-
-
-
Setting 2
Protocol Type. The different Wiegand
readers are able to read card with
different protocols. The IP reader
software will enable you to select one
of the protocols.
(Remark ”all types” in setting 0
means All types except 2 and 128-
255.)
0
All types
except value
2 and 128-
255
-
-
1
H10301
26
8 bit
2
H10302
37
none
3
H10304
37
16 bit
4
H10306
34
16 bit
5
C1000
35
12 bit
8
ARAS 36
36
16 bit
128
NFP
37
16 bit
129
NFP1
36
15 bit
130
PAL
34
0 bit
131
PAH
27
0 bit
255
RAW
--
0 bit
Setting 3
Facility code. This is a part of the
data delivered by the Wiegand
protocol. If the value here is other
then '0', then the IP reader will check
if the code on the card is present. If
the value is '0' the facility code is not
checked.
-
-
-
-
Data 1
Not applicable
-
-
-
-
Data 2
Not applicable
-
-
-
-
Note: The facility code is never send to the server.
Summary of Contents for IP Card Reader
Page 6: ...I Introduction Part...
Page 8: ...II Components Part...
Page 11: ...III Operating Procedures Part...
Page 13: ...IV Communication Part...
Page 15: ...Communication 10 IP Reader encryption protocol...
Page 16: ...V Network Connections Part...
Page 19: ...VI LEDs Light Emitting Diodes Part...
Page 20: ...15 Inepro IP Reader Konica Minolta LEDs Light Emitting Diodes...
Page 24: ...VII Relays Part...
Page 27: ...VIII Software configuration settings Part...
Page 35: ...IX Inepro Business Server Optional Part...
Page 40: ...X Specifications Part...
Page 42: ...XI Appendix I Part...
Page 43: ...Appendix I 38...
Page 44: ...XII Notes Part...
Page 45: ...Notes 40 Notes This area is meant for the reader s notes...
Page 46: ......