background image

 

 

 

Industrial Water Equipment Ltd

 

44 New Street, Matlock, Derbyshire. DE4 3DN

 

[email protected]          www.industrialwaterequipment.co.uk

 

 

01629 55839

 

 

System Installation

 

 

NOTE : All units are quality tested at the factory. All units are rated up to 12 bar. Mount your ultraviolet 
steriliser    horizontally or vertically on a level and firm surface. Do not lay the system on the ground or 
where water may puddle. Do not submerge. Install sterilizer equipment in a readily accessible and well 
lit location to facilitate inspection and maintenance. On all units allow space to change the UV lamp and 
Quartz sleeve (typically leave a maintenance space equal to the overall UV system length) and other 
parts.   

 

Installation Instructions   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 1:

 Open the package and check you have all the components: 

 

Reactor Chamber, 

 

UV Lamp, 

 

Quartz Sleeve, 

 

O-ring, 

 

Electronic Ballast and Support.

 

 

Step 2:

 Ensure the quartz sleeve and UV lamp are thoroughly clean before starting to install. 

This can be done with alcohol or a mild detergent. Always wear soft non-abrasive gloves to keep 
any finger marks away from them.

 

Step 3:

 Remove the end nut from the Reactor Chamber.

 

 

Step 4:

 

Insert the spring into the quartz sleeve.

 

 

Summary of Contents for ST08 Series

Page 1: ...d 44 New Street Matlock Derbyshire DE4 3DN Info industrialwaterequipment co uk www industrialwaterequipment co uk 01629 55839 1 Installation Operation and Maintenance Manual For IWE ST08 Series Ultraviolet Disinfection Water System ...

Page 2: ...al electrical shock when water is in close proximity to this electrical system User must always disconnect power before performing any maintenance on this system This UV system must be grounded Avoid exposure to direct or strongly reflected germicidal ultraviolet rays Germicidal ultraviolet rays are harmful to the eyes and skin If necessary please wear safety goggles to protect your eyes CAUTION R...

Page 3: ... UV A UV B and UV C UV C or short wave ultraviolet occurs between 200 280nm and the optimum UV germicidal action at 265nm UV light has a useful and strong disinfection ability which can physically eradicate microorganisms by altering their DNA or RNA which is done effectively and without the use of chemicals CAUTION Because ultraviolet light is not visible to the human eye we can sometimes ignore ...

Page 4: ...moving parts which are prone to wearing out and are easy to install wherever required Product Specification Ultraviolet Disinfection water systems come in a variety of sizes and can be used to purify the water for a single faucet or for an entire home or larger building The UV is simple and safe equipment that is suitable for small residential applications and large commercial projects Reactor Cha...

Page 5: ...lit location to facilitate inspection and maintenance On all units allow space to change the UV lamp and Quartz sleeve typically leave a maintenance space equal to the overall UV system length and other parts Installation Instructions Step 1 Open the package and check you have all the components Reactor Chamber UV Lamp Quartz Sleeve O ring Electronic Ballast and Support Step 2 Ensure the quartz sl...

Page 6: ...l the O ring onto the open end of the quartz sleeve Step 6 Insert the quartz sleeve into the Reactor Chamber Step 7 Hand screw the end nut onto the Reactor Chamber In order to protect the O ring do not over tighten Step 8 Connect the 4 pin electrical socket with the UV lamp pins tightly Step 9 Very carefully insert the quartz sleeve through the end nut onto the UV lamp ...

Page 7: ...n submerged in water 4 DO NOT operate your UV if the cord or plug is damaged the unit has been dropped or if it starts to malfunction 5 Install your filter on the return line This will guarantee that the water does not have any debris or Step 11 Insert the earth cable tightly Step 13 Select a readily accessible and well it location to fix the system The system should always be located closest to t...

Page 8: ... from any bacterial contaminants The decontamination process must be done as soon as you install the UV and repeated whenever the UV has to be shut down for any reason Disinfection process 1 Turn off the upstream water supply that feeds the reactor chamber and then depressurise water system 2 Remove the pre filter cartridge and then add 250 500ml of household bleach or chlorine 5 25 into the empty...

Page 9: ... to do this is to pull it out at a straight not at an angle until it is completely out 7 To reinstall the lamp follow steps 7 to 11 NOTE When you have replaced the lamp remember to reset the lamp life timer How to replace the quartz sleeve 1 Turn the off at the power supply 2 Turn off the water supply to your UV s inlet and outlet valves 3 Remove the drain plug and drain the chamber once this is d...

Page 10: ...to the quartz sleeve b Step 5 Install the O ring onto the open end of the quartz sleeve c Step 6 Insert the quartz sleeve into the Reactor Chamber 11 To re install the new lamp see the lamp installation instructions 12 Slowly restore the water supply to your UV and check for leaks 13 Turn on power UV FAQ s To help you keep your UV in optimum operation condition see our most popular FAQ s Should a ...

Page 11: ...lt has meant that Phillips bulb contain the lowest amount of mercury in the industry Quartz Sleeve The quartz sleeve in your UV is a made from high quality industrial technology glass which has substantial and chemical properties Your quartz sleeve can stop a spectrum transmission less than 220 nm and prevent any radiation of high density UV rays and will not generate an ozone UV transmissions can...

Page 12: ... be reset to 7 days but displaying A3 These steps can be repeated 4 times after which the alarm can no longer be cancelled unless the uv lamp is replaced When the UV Lamp fails The timer on the lamp life will stop counting while ballast life counting will continue Alarm The red light will be flashing whilst the buzzer sounds for 1 second then stops for 5 4 Replace the lamp and reset the time Disco...

Page 13: ...fo industrialwaterequipment co uk www industrialwaterequipment co uk 01629 55839 13 Typical UV Installation One year guarantee For more information visit our website at www industrialwaterequipment co uk or contact one of our sale team on sales industrialwaterequipment co uk ...

Reviews: