Ref. IS.MDUINO.58+
Rev. 0: 30-08-2019
26
7.2
B Zone (Analog Shield)
1
See section 8 to select suitable switch configuration for enable these connections.
B Zone
M
-D
ui
no
C
onnec
tor
A
rd
u
ino
P
in
Fun
c
tion
I0.12
I0.11
I0.10
I0.9
I0.8
I0.7
(-)I0.6/INT1
I0.6/INT1
1
(-)I0.5/INT0
I0.5/INT0
1
(-)I0.4
I0.4
(-)I0.3
I0.3
(-)I0.2
I0.2
(-)I0.1
I0.1
(-)I0.0
I0.0
59
58
57
56
55
54
-
3
-
2
-
26
-
25
-
24
-
23
-
22
Analog/ Digital In
Analog/ Digital In
Analog/ Digital In
Analog/ Digital In
Analog/ Digital In
Analog/ Digital In
GND I0.6
Interrupt 1 In
GND I0.5
Interrupt 0 In
GND I0.4
Digital Input
GND I0.3
Digital Input
GND I0.2
Digital Input
GND I0.1
Digital Input
GND I0.0
Digital Input
B Zone
M
-D
ui
no
C
onnec
tor
A
rd
u
ino
P
in
Fun
c
tion
GND
A0.7
1
A0.6
1
A0.5
1
Q/Vdc
COM(-)
Q0.7
1
Q0.6
1
Q0.5
1
Q0.4
Q0.3
Q0.2
Q0.1
Q0.0
GND
6
5
4
-
-
6
5
4
40
39
38
37
36
GND
Analog Out
Analog Out
Analog Out
External Isolated Out Vdc
External Isolated Out GND
Digital/PWM Out
Digital/PWM Out
Digital/PWM Out
Digital Out
Digital Out
Digital Out
Digital Out
Digital Out
Led indicator I/Os state
Analog/Digital Inputs
Interrupt Inputs (isolated)
Digital Inputs (isolated)
Configuration Switch*
(see section 8 to select the correct
configuration for outputs).
Analog Outputs
Voltage Supply/Reference for
Digital/PWM Outputs (isolated)
PWM/Digital Outputs
Top Zone
Summary of Contents for M-DUINO PLC ARDUINO ETHERNET 58
Page 2: ...Ref IS MDUINO 58 Rev 0 30 08 2019 1...
Page 3: ...Ref IS MDUINO 58 Rev 0 30 08 2019 2 Ethernet PLC MDuino 58 PLUS User Guide Revised August 2019...
Page 43: ...Ref IS MDUINO 58 Rev 0 30 08 2019 42 Typical Connections 13...
Page 44: ...Ref IS MDUINO 58 Rev 0 30 08 2019 43...
Page 45: ...Ref IS MDUINO 58 Rev 0 30 08 2019 44...
Page 46: ...Ref IS MDUINO 58 Rev 0 30 08 2019 45...