![background image](http://html1.mh-extra.com/html/industrial-shields/m-duino-plc-arduino-ethernet-58/m-duino-plc-arduino-ethernet-58_manual_2054258013.webp)
Ref. IS.MDUINO.58+
Rev. 0: 30-08-2019
12
1.2
Zone Distribution
The distribution of the different features that provide the M-Duino 58 I/Os PLUS is the
following one:
Shield
B Zone
C Zone
D Zone
Analog Shield
13 Inputs
(13 Digital inputs,
6 of which can
work as Analog
Input)
8 Outputs
(8 Digital Outputs,
3 of which can
work as Analog
Output)
13 Inputs
(13 Digital inputs,
6 of which can
work as Analog
Input)
8 Outputs
(8 Digital Outputs,
3 of which can
work as Analog
Output)
11 Inputs
(11 Digital Inputs,
4 of which can
work as Analog
Input)
6 Outputs
(6 Digital Outputs,
2 of which can
work as Analog
Outputs