Chapter 6 - Hardware Reference
6-10
S21, S22, S23 Hybrid Step Motor Specifications
Electrical Specs.
S21T
S21V
S22T
S22V
S23T
S23V
Continuous Stall Torque oz-in [N-m]
65 [0.46]
100 [0.71]
125 [0.88]
Recommended Current/Phase Amps
1.05
2.1
1.5
3.0
1.75
3.5
Winding Resistance @ Ambient Ohms
5.4
1.35
4.8
1.2
4.4
1.1
Inductance mH
18
4.5
18
4.5
18
4.5
Max. Winding Temperature °F [°C]
212 [100]
212 [100]
212 [100]
Mechanical Specs.
S21T
S21V
S22T
S22V
S23T
S23V
Rotor Inertia oz-in-s
2
[kg-m
2
] 1.66x10
-3
[1.17x10
-5
]
3.31x10
-3
[2.34x10
-5
]
4.97x10
-3
[3.51x10
-5
]
Axial Shaft Load lbs [N]
25 [111]
25 [111]
25 [111]
Radial Shaft Load @ 0.5 inches lbs [N]
5.6 [25]
5.6 [25]
5.6 [25]
Motor Weight lbs [kg]
1.6 [0.73]
2.4 [1.1]
3.2 [1.5]
Step Angle (full step) degrees
1.8
1.8
1.8
Notes:
• T = Series V = Parallel
• Parallel (V) wiring: 50% duty cycle
max above 5 rps (300 rpm).
• IDC step motors require a torque
safety margin of at least 30%.
.002 A
A
.003
.002
A
IDC Motor Wiring
Series
YELLOW
WHT/YEL
WHT/RED
RED
SHIELD
BLACK
WHT/BLK
WHT/ORG
ORANGE
Parallel
YELLOW
WHT/RED
RED
WHT/YEL
SHIELD
BLACK
WHT/ORG
ORANGE
WHT/BLK
Summary of Contents for Impulse PCW-5181
Page 2: ......
Page 4: ......
Page 8: ...Chapter 1 Overview 1 2 This page intentionally left blank...
Page 10: ...Chapter 2 Shipping Contents 2 2 This page intentionally left blank...
Page 24: ...Chapter 3 Connecting and Installing Your Impulse 3 14 This page intentionally left blank...
Page 90: ...Chapter 6 Hardware Reference 6 14 This page intentionally left blank...
Page 94: ...Chapter 7 Troubleshooting Your Impulse 7 4 This page intentionally left blank...
Page 98: ...Appendix A Recommended Wiring Practices A 2...
Page 119: ...Do Not Print This Page Inserted as Placeholder...