Chapter 6 - Hardware Reference
6-5
Step, Direction, and Shutdown Inputs
Fault Output
2.2n 50V
COM
COM
237
4.99K
4.99K
+5V
4.99K
AM26LS32
DIFFERENTIAL
DRIVER
STEP-
DIR-
SD-
STEP+
DIR+
SD+
Single-Ended
Installation
Application Notes:
1.When wiring TTL signals to other manufacturer’s indexers, the Step TTL command signals from
the controller should be wired to
Step +
, the Direction signal to
Dir +
, and the Shutdown signal
to
SD +
(
Step -
,
Dir -,
and
SD -
should not be connected). Remember to connect commons.
2.Activating the Shutdown input (logic low) disables the drive amplifier and de-energizes the motor.
When this input is off (logic high) the drive is enabled and the motor is energized.
external
Impulse internal
Impulse internal
external
Differential
Installation
2.2n 50V
237
4.99K
4.99K
4.99K
COM
COM
COM
+5V
STEP-
DIR-
SD-
STEP+, DIR+, SD+
SINKING
OUTPUT
COM
237
+5V
FAULT
FAULT+
FAULT-
4N35
NC
FAULT+
FAULT-
FAULT+
FAULT-
EQUIVALENT
CIRCUITS
external
Impulse internal
Drive Faulted
No Fault Present
Summary of Contents for Impulse PCW-5181
Page 2: ......
Page 4: ......
Page 8: ...Chapter 1 Overview 1 2 This page intentionally left blank...
Page 10: ...Chapter 2 Shipping Contents 2 2 This page intentionally left blank...
Page 24: ...Chapter 3 Connecting and Installing Your Impulse 3 14 This page intentionally left blank...
Page 90: ...Chapter 6 Hardware Reference 6 14 This page intentionally left blank...
Page 94: ...Chapter 7 Troubleshooting Your Impulse 7 4 This page intentionally left blank...
Page 98: ...Appendix A Recommended Wiring Practices A 2...
Page 119: ...Do Not Print This Page Inserted as Placeholder...