Chapter 4 - Configuring Impulse with Application Developer
4-19
Setup - Editing Stored Moves
later in this chapter for more information on Home moves.
Jog +
:
Activation of a Jog+ input will jog the motor at the acceleration rate specified by the Jog
Accel parameter and the velocity specified by the current state of a
Jog Speed
input in the positive
direction. If a
Jog Speed
input has not been configured, the motor is jogged at the velocity specified
by the Jog-Low parameter.
Jog -
:
Activation of a Jog- input will jog the motor at the acceleration rate specified by the Jog Accel
parameter and the velocity specified by the current state of a
Jog Speed
input in the negative
direction. If a
Jog Speed
input has not been configured, the motor is jogged at the velocity specified
by the Jog-Low parameter.
Jog Speed
:
The
Jog Speed
input toggles between the low and high velocities for the
Jog+
and
Jog-
inputs as specified by the Jog-Low and Jog-High parameters. If the state of
Jog Speed
input is
changed while a
Jog+
or a
Jog-
input is asserted, the motor will accel or decel at the Jog Accel rate
to the high or low velocity respectively.
Kill
:
Activation of a
Kill
input terminates any motion (external steps or internal move engine)
instantly without a deceleration ramp.
Move Select
:
The
Move Select
input is used to trigger one of the 7 possible stored moves (Motion
Node option only). Each configured
Move Select
input serves as a bit in a 3-bit binary number
therefore allowing the binary representation of numbers 0-7. The
Move Select
configuration option
is only available on inputs #1-#3 with input #1 being the least significant bit (LSB) and input #3
being the most significant bit (MSB). Note that the bit places are
fixed
with respect to the input
numbers. For example, if input #1 were configured as an
EOT
and input #2 were configured as a
Move Select,
asserting input #2 would run stored move #2
not
stored move #1. Below is a
Move
Select
assertion table:
To guard against inadvertently selecting moves during input transitions, all
Move Select
inputs must
be stable for the time specified by the Move Select Input Scan Time. See the “Editing Stored Moves”
section for more information on setting the Move Select Input Scan Time.
Stop
:
Activation of a
Stop
input terminates any motion (external steps or internal move engine) at
the rate specified by the Stop Rate parameter.
Warm Boot
:
Activation of a
Warm Boot
input resets the drive and clears any latched fault
condition. To guard against a
Warm Boot
input being inadvertently held asserted, the
Warm Boot
input is negative edge triggered (activation on to activation off). To insure the negative edge is
latched, the
Warm
Boot
input must be held asserted for at least 500
µ
s before releasing.
Move Select Inputs
Input #3 State
Input #2 State
Input #1 State
Result
Inactive
Inactive
Inactive
Idle
Inactive
Inactive
Active
Run Stored Move #1
Inactive
Active
Inactive
Run Stored Move #2
Inactive
Active
Active
Run Stored Move #3
Active
Inactive
Inactive
Run Stored Move #4
Active
Inactive
Active
Run Stored Move #5
Active
Active
Inactive
Run Stored Move #6
Active
Active
Active
Run Stored Move #7
Summary of Contents for Impulse PCW-5181
Page 2: ......
Page 4: ......
Page 8: ...Chapter 1 Overview 1 2 This page intentionally left blank...
Page 10: ...Chapter 2 Shipping Contents 2 2 This page intentionally left blank...
Page 24: ...Chapter 3 Connecting and Installing Your Impulse 3 14 This page intentionally left blank...
Page 90: ...Chapter 6 Hardware Reference 6 14 This page intentionally left blank...
Page 94: ...Chapter 7 Troubleshooting Your Impulse 7 4 This page intentionally left blank...
Page 98: ...Appendix A Recommended Wiring Practices A 2...
Page 119: ...Do Not Print This Page Inserted as Placeholder...