background image

System1000_GB_130705.doc  

Page 

13 

20.  Guarantee Conditions 

The following conditions that describe preconditions and extent of our guarantee leave the dealer’s 

warranties according to the purchase contract untouched. 

Before sending a product back or handing it to your dealer, please contact our helpline to discuss the 

problem in advance. Maybe your problem can be solved by phone. 

We offer the following guarantee to the first purchaser of this product: 

According to the following conditions (No. 2-7), we will repair any damage caused to the product 

due to faulty workmanship, if it was reported to us immediately after noticing and within 24 

months from delivery. This guarantee does not apply to minor differences from standard quality 

that are irrelevant for value and performance capability of the product and to damage resulting 

from chemical or electrochemical effects of water or abnormal environmental conditions. 

We will repair free of charge faulty parts or, at our discretion, exchange them for faultless parts. 

Exchanged parts will become our property. 

The guarantee expires, if repairs or modifications are carried out by unauthorized persons or if our 

products are provided with accessories that are not suitable for them. The guarantee also expires if 

modifications of original parts are carried out. 

Repairs or exchanges carried out under guarantee do not extend the guarantee period and do not 

start a new guarantee period. The guarantee period for spare parts ends with the guarantee period 

for the complete product. 

The guarantee is always limited to the customary price of the product. 

Further claims, especially claims for damages that occur to persons or things other than the product 

are excluded, as long as no liability is ordered by law. No compensation can be claimed in the case 

of burglary or failure of the product. 

Please send the faulty product free of domicile. Shipments that are not free of domicile will not be 

accepted. Repairs can only be carried out if an explicit description of the faults is supplied. Please 

send in only complete systems that are well packaged. 

 

NOTE: An alarm system can only be seen as a supplement to mechanical security measures. It is no 

substitute for your duties of care and for sufficient insurance cover. 

 

 
21. Appendix: Wirefree Door-Contact 1000 M (optional) 

The optional door contact can be used to secure single doors or windows. The door contact contains a 

reed contact that is closed by a magnet on the opposite side. If the magnet is removed, the contact 

opens, and an alarm signal is transmitted to the siren. 

 

 

21.1. Coding 

 

When you receive the door contact, it is not factory preset to any special code. Please follow the 

instructions on the packaging of the door contact 1000 M to adjust the code to your system. 

 

 

21.2  Fitting the Battery 

The door contact is supplied with a battery. To operate the door contact, slowly pull out the protective 

tab. (If this is difficult, loosen the screws at the back of the casing, and retighten them after pulling out 

the protective tab.) 

 

 

 

 

  

    

 

 

 

 

fig. 21

 

Summary of Contents for 1000 R

Page 1: ...nts 2 15 Changing the Batteries 10 4 Safety Notes 2 16 Troubleshooting 11 5 Declaration of Conformity 2 17 Maintenance 11 6 How the System Works 3 18 Specifications 11 7 Planning your System 3 19 Optional Accessories 12 8 Accessories 4 20 Guarantee Conditions 13 9 Coding 4 21 Appendix Door Contact 10 Fitting the Batteries 5 optional 13 11 Checking the Components 6 22 Drilling Template 16 12 Instal...

Page 2: ...illing make sure that there are no electric cables hidden in the wall As the siren is very loud ensure that it is not operated close to a person s ear especially a child s ear Do not mount the control panel close to metal fittings or other objects which may disturb radio signal transmission Do not install any damaged units e g by shipping damage If in doubt ask your customers service or supplier R...

Page 3: ...anti tamper switch protects the siren against tampering However you should install the siren as high as possible to make tampering more difficult The siren is for outdoor use but it should be protected from direct rain The siren should be installed at a place where it can reach the radio signals transmitted by the keyfob You should also be able to hear the bleeping sounds of the siren Your propert...

Page 4: ...tains two PIRs and a wirefree remote keyfob The system can easily be expanded by adding additional PIRs Additional keyfobs are also available You can protect doors and windows with the door contacts available as accessories Accessory components must be adjusted to the codes of the original system before use This system will not work with wirefree accessories from other wirefree alarm systems see s...

Page 5: ...sert six D cell alkaline batteries typeLR 20 or MN 1300 in the compartments so they face the same direction and have the same polarity Now the siren must learn the house code from the keyfob Turn the Power On Off switch on the keyfob to ON The LED illuminates for 20 seconds signalling the self learn period Press the Power On Off button on the keyfob within the 20 seconds Two bleeps are heard and t...

Page 6: ...panic alarm is activated WARNING The siren is loud Take precautions to prevent damage to your hearing 11 3 PIR Sensors First check the radio link to the siren Place a PIR sensor on a table or on the floor and wave a hand in front of the lens The LED behind the lens will flash if the LED and the power saver jump link are still covered The LED on the bottom of the siren should also flash once Check ...

Page 7: ... PIR will send a signal to the siren when it is triggered whether the system is armed or not Removing the power saver link provides an off period of approx five minutes between two radio signals to save battery power If you want to test your system you have to wait five minutes to avoid the effects of the off period After having installed and checked the PIR sensors you should remove both power sa...

Page 8: ...vate If this happens press the OFF button on the keyfob 12 5 Installing the Siren Use the template supplied section 22 and mark the positions for the four fixing holes Check by the template that the anti tamper spring will not be positioned over a hollow in the mounting surface If it does change the fixing location or disable the anti tamper switch by covering both pins with the link Drill the fou...

Page 9: ... bleeps Disarmed siren has been triggered Full siren Siren sounds for 2 minutes for 15 seconds in the case of tampering and then resets automatically 14 Anti Jamming The System is fitted with an anti jamming circuit If it receives an unwanted radio signal for more than 30 seconds it will trigger the siren for 15 seconds and then revert back to the previous status The anti jamming circuit is factor...

Page 10: ...erated normally the LED flashes after each command If the LED does not flash the batteries need to be replaced The operational life of the batteries in the siren depends on the type of the batteries their use and the light conditions for the solar cells Replace the batteries by six alkaline mono cells of good quality 15 4 Battery Safety Notes Use only alkaline batteries of good quality Do not use ...

Page 11: ...ance between the PIR or the keyfob and the siren is too long Shorten the distance The radio link is disturbed 17 Maintenance We recommend that you check the batteries in the PIRs every six months and if necessary replace them The batteries can be checked by arming the system and triggering the sensor remember the off period of the PIR The siren should sound If the siren does not react or the siren...

Page 12: ...oving the jump link Power saving off period of 5 minutes between signals can be enabled with power saver jump link Operating temperature 0 C to 40 C Use indoors Wirefree keyfob1000 R Transmitter frequency 433 92 MHz Range max 30m outdoors Coding 10 digit code wire links Operating voltage 12 V DC Battery type 23A 12 V Display LED Operating temperature 10 C to 50 C 19 Accessories The system can be e...

Page 13: ... new guarantee period The guarantee period for spare parts ends with the guarantee period for the complete product The guarantee is always limited to the customary price of the product Further claims especially claims for damages that occur to persons or things other than the product are excluded as long as no liability is ordered by law No compensation can be claimed in the case of burglary or fa...

Page 14: ...e system press the OFF button on the keyfob Before installing the door contact also check the function in the position where you want to install it 21 4 Installation The magnet is fixed to the door or window and the door contact to the door or window frame or vice versa this does not affect the function of the door contact The parts can be installed on the right or left side of a door or window th...

Page 15: ...ed or with screws When installing the door contact to a window pay attention to the length of the screws Then fit the four caps over the screw holes 21 5 Changing the Battery If the LED on the door contact flashes red when the door contact is opened the battery needs to be replaced Remove the two screws and separate the casing Insert a new battery 12 V type 23A and replace the casing fig 25 fig 26...

Page 16: ... than the template The anti tamper spring must be positioned on the same level as the back of the casing otherwise the siren will sound WARNING If the anti tamper switch is enabled do not take the siren off the wall after the anti tamper spring is depressed If the siren sounds press the OFF button on the keyfob to silence the alarm Indexa GmbH Paul Böhringer Str 3 D 74229 Oedheim position of the a...

Reviews: