23 of 37
Indesit
Company
Service Manual UK
English
COMPONENT DESCRIPTION
B Energy Model differences:
- B Energy Machine Differences
- Insulation Pad on Heater Cover
- Settings File with an energy saving profile (see module below)
Door
The Door is constructed of several
components, with an Easy Clean Door Bowl
and inner and outer door panels that are
screwed together.
The Door is NOT reversible.
.
Filter
Comprises of a plastic mesh moulded into its housing, which slides into the front air duct.
Door Switch
Normally open single pole microswitch activated by the door on closure. This is the first switch in the
electrical circuit and therefore its rating corresponds to the full loading of the product.
Control Module
This is an Electronic Device that monitors and controls all devices within the tumble dryer.
A production module is pre programmed at the factory with the relevant programmed file.
Service Modules are supplied non programmed and it is necessary for the Module to be
programmed by the Service Engineer.
See pages 30 & 31 for Module programming.
B Energy Models
B Energy models include an energy saving feature with an intelligent dryness algorithm. During the
later stages of the of the cycle, when the clothes are nearly dry, the module by accurately monitoring
the temperature in side the drum is able to reduce the heater on time, saving energy. This energy
saving profile is held within the settings file.
Heater Unit
The heater is fixed by screws to the rear cover. The heater elements, thermal controls, thermistors and
rear cover are supplied as an assembly and has Five and Two way connectors provided to interface with
the electronic module. The heater has an upper and lower heater. The lower (static) heater is
permanently energised and the upper heater (dynamic) is cycled on and off by the control module during
a programme to maintain the correct temperature for the programme selected.
One-Shot (Safety) Thermostat (White Spot)
This device is a disc type thermostat set to operate at 143°C. It is used as a safety device.
It is positioned above the element. If this device fails it cannot be reset.
Note: If the One-Shot (safety) thermostat operates (opens) the dryer will continue with the
cycle without heating or drying the clothes. No fault code will display.
Water container
Filter
Condenser cover
Rating plate
Model & Serial numbers
Condenser cover handle
(Pull to open)
Air intake grille