•  Setting the burners to minimum

1.  Turn the tap to the low flame position;

2.  Remove the knob and adjust the adjustment 

screw, which is positioned in or next to the tap 

pin, until the flame is small but steady.

3.  Having adjusted the flame to the required low setting, while the burner is 

alight, quickly change the position of the knob from minimum to maximum 

and vice versa several times, checking that the flame does not go out.

4.  Some appliances have a safety device (thermocouple) fitted. If the device 

fails to work when the burners are set to the low flame setting, increase 

this low flame setting using the adjusting screw.

5.  Once the adjustment has been made, replace the seals on the by-passes 

using sealing wax or a similar substance.

!

 If the appliance is connected to liquid gas, the regulation screw must be 

fastened as tightly as possible.

!

 Once this procedure is finished, replace the old rating sticker with one 

indicating the new type of gas used. Stickers are available from any of our 

Service Centres.

!

 Should the gas pressure used be different (or vary slightly) from the 

recommended pressure, a suitable pressure regulator must be fitted to the 

inlet pipe (in order to comply with current national regulations).

Electrical 

connections

DATA PLATE

ECODESIGN

see data plate

This appliance conforms to the EU Regulation no.  66/2014 

implementing Directive 2009/125/EC.   

standard EN 30-2-1

Summary of Contents for PAA 642 /I(WH)

Page 1: ...Instructions HOB Contents Operating Instructions 1 Warnings 2 Assistance 3 Description of the appliance 4 Installation 5 Start up and use 9 Precautions and tips 9 Maintenance and care 10 Troubleshooti...

Page 2: ...ce Cleaning and user maintenance shall not be made by children without supervision WARNING Unattendedcookingonahobwithfator oil can be dangerous and may result in fire NEVER try to extinguish a fire w...

Page 3: ...e data plate located on the appliance The following information are applicable only for the UK and Republic of Ireland Repairs and After Sales For product help and advice repairs spare parts or access...

Page 4: ...URNERS 5 SAFETY DEVICES GASBURNERSdifferinsizeandpower Usethediameterofthecookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the size of the flame GASBURN...

Page 5: ...ontainingLPGcylindersmustalsobeequippedwithventstoallow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or...

Page 6: ...ack or Blue FAILURE TO OBSERVE THE ACCIDENT PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OFALL LIABILITY Gas connection The appliance should be connected to the main gas supply or to a gas cylinde...

Page 7: ...using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid gas the regulation screw must b...

Page 8: ...YPE OF BURNER NOZZLE RATED THERMAL FLOW RATE kW RATED CONSUMPTION REDUCED HEAT CAPACITY kW GAS PRESSURE mbar min rat max 3 00 1 75 1 00 286 l h 167 l h 95 l h 218 g h 127 g h 73 g h 0 60 0 35 0 30 0 6...

Page 9: ...tions provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was des...

Page 10: ...ure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation Ch...

Page 11: ...GB 11...

Page 12: ...12 GB Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www indesit com 195145229 00 04 2016 XEROX FABRIANO...

Reviews: