background image

GB

5

Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 

of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a qualified professional according to the 

instructions provided. Incorrect installation may cause harm to people and 

animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms 

in accordance with current national regulations. The following requirements 

must be observed:

•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 

automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power. 

The air circulation system may take air directly 

from the outside by means of a pipe with an 

inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 

of blockages.

The system can also provide the air needed for 

combustion indirectly, i.e. from adjacent rooms 

fitted with air circulation tubes as described 

above. However, these rooms must not be 

communal rooms, bedrooms or rooms that 

may present a fire hazard.

•  Intensive and prolonged use of the appliance may necessitate 

supplemental ventilation, e.g. opening a window or increasing the power 

of the air intake system (if present).

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 

gas to escape in the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored in rooms or 

storage areas that are below ground level (cellars, etc.). It is advisable to 

keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources (ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

Fitting the appliance

The following precautions must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 650 mm from the hob (see figure).

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob (see figure).

If the hob is installed beneath a wall cabinet, 

the latter must be situated at a minimum of 700 

mm above the hob.

•  The installation cavity should have the dimensions indicated in the figure. 

NOTE:

 In case of installation of a hood above the hob, please refer to the 

hood instructions for the correct distance.

•  After having cleaned the perimeter surface, apply the supplied gasket to 

the hob as shown in the figure.

 

Position the hob in the worktop opening made respecting the dimensions 

indicated in the Instruction.

NOTE: the power supply cable must be long enough to permit its upward 

extraction.

To secure the hob, use the brackets 

(A) 

provided with it. Fit the brackets into the 

relevant bores shown by the arrow and fasten them by means of their screws 

in accordance with the thickness of the worktop (see the following figures).

Top 20 mm

 

Top 30-50 mm

•  Where the hob is not installed over a built-in oven, a wooden panel must 

be installed as insulation. This must be placed at a minimum distance of 

20 mm from the lower part of the hob.

600mm min.

420mm min.

650mm min.

Summary of Contents for PAA 642 /I(WH)

Page 1: ...Instructions HOB Contents Operating Instructions 1 Warnings 2 Assistance 3 Description of the appliance 4 Installation 5 Start up and use 9 Precautions and tips 9 Maintenance and care 10 Troubleshooti...

Page 2: ...ce Cleaning and user maintenance shall not be made by children without supervision WARNING Unattendedcookingonahobwithfator oil can be dangerous and may result in fire NEVER try to extinguish a fire w...

Page 3: ...e data plate located on the appliance The following information are applicable only for the UK and Republic of Ireland Repairs and After Sales For product help and advice repairs spare parts or access...

Page 4: ...URNERS 5 SAFETY DEVICES GASBURNERSdifferinsizeandpower Usethediameterofthecookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the size of the flame GASBURN...

Page 5: ...ontainingLPGcylindersmustalsobeequippedwithventstoallow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or...

Page 6: ...ack or Blue FAILURE TO OBSERVE THE ACCIDENT PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OFALL LIABILITY Gas connection The appliance should be connected to the main gas supply or to a gas cylinde...

Page 7: ...using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid gas the regulation screw must b...

Page 8: ...YPE OF BURNER NOZZLE RATED THERMAL FLOW RATE kW RATED CONSUMPTION REDUCED HEAT CAPACITY kW GAS PRESSURE mbar min rat max 3 00 1 75 1 00 286 l h 167 l h 95 l h 218 g h 127 g h 73 g h 0 60 0 35 0 30 0 6...

Page 9: ...tions provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was des...

Page 10: ...ure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation Ch...

Page 11: ...GB 11...

Page 12: ...12 GB Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www indesit com 195145229 00 04 2016 XEROX FABRIANO...

Reviews: