PAA 642 /I(WH)

NATURAL GAS

(Methane)  

17

20

25

 

 

LIQUEFIED 

PETROLEUM GAS

(Butane)   

G30

28

30

Model configuration 

4 BURNERS

Rated thermal

flow rate (kW)

 

Total rated

consumption 

Air required (m  ) for

3

burning 1 m3 of gas

Rapid

Semi-Rapid

Auxiliary

Rapid

Semi-Rapid

Auxiliary

G20

F2 118

95Z
72X

85
63
50

Burner and nozzle specifications

Table 1

TYPE OF GAS

USED

TYPE OF 

BURNER

NOZZLE

RATED 

THERMAL 

FLOW RATE

kW

RATED 

CONSUMPTION

REDUCED 

HEAT 

CAPACITY

kW

GAS PRESSURE

mbar

min.       rat.      max.

3.00
1.75
1.00

286 l/h
167 l/h

95 l/h

218 g/h
127 g/h

73 g/h

0.60
0.35
0.30

0.60
0.35
0.30

G20

 20 mbar 

                 1R - 2S -1A                               7.50                             715 l/h                                9.52     

G30

 28-30 mbar 

                 1R - 2S -1A                               7.50                             545 g/h                             30.94     

Type of gas used

ELECTRIC SUPPLY: 220-240V~   50/60Hz   0,6W

 CATEGORY  II2H3+

LIQUEFIED 

PETROLEUM GAS

(Propane)    

G31

Rapid

Semi-Rapid

Auxiliary

214 g/h
125 g/h

71 g/h

0.60
0.35
0.30

25

37        45

20

35

G31

 37 mbar 

                 1R - 2S -1A                               7.50                             535 g/h                             23.80     

85
63
50

3.00
1.75
1.00

3.00
1.75
1.00

Summary of Contents for PAA 642 /I(WH)

Page 1: ...Instructions HOB Contents Operating Instructions 1 Warnings 2 Assistance 3 Description of the appliance 4 Installation 5 Start up and use 9 Precautions and tips 9 Maintenance and care 10 Troubleshooti...

Page 2: ...ce Cleaning and user maintenance shall not be made by children without supervision WARNING Unattendedcookingonahobwithfator oil can be dangerous and may result in fire NEVER try to extinguish a fire w...

Page 3: ...e data plate located on the appliance The following information are applicable only for the UK and Republic of Ireland Repairs and After Sales For product help and advice repairs spare parts or access...

Page 4: ...URNERS 5 SAFETY DEVICES GASBURNERSdifferinsizeandpower Usethediameterofthecookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the size of the flame GASBURN...

Page 5: ...ontainingLPGcylindersmustalsobeequippedwithventstoallow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or...

Page 6: ...ack or Blue FAILURE TO OBSERVE THE ACCIDENT PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OFALL LIABILITY Gas connection The appliance should be connected to the main gas supply or to a gas cylinde...

Page 7: ...using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid gas the regulation screw must b...

Page 8: ...YPE OF BURNER NOZZLE RATED THERMAL FLOW RATE kW RATED CONSUMPTION REDUCED HEAT CAPACITY kW GAS PRESSURE mbar min rat max 3 00 1 75 1 00 286 l h 167 l h 95 l h 218 g h 127 g h 73 g h 0 60 0 35 0 30 0 6...

Page 9: ...tions provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was des...

Page 10: ...ure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation Ch...

Page 11: ...GB 11...

Page 12: ...12 GB Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www indesit com 195145229 00 04 2016 XEROX FABRIANO...

Reviews: