8
GB
S
S
A
R
PAA 642 /I(WH)
NATURAL GAS
(Methane)
17
20
25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
28
30
Model configuration
4 BURNERS
Rated thermal
flow rate (kW)
Total rated
consumption
Air required (m ) for
3
burning 1 m3 of gas
Rapid
Semi-Rapid
Auxiliary
Rapid
Semi-Rapid
Auxiliary
G20
F2 118
95Z
72X
85
63
50
Burner and nozzle specifications
Table 1
TYPE OF GAS
USED
TYPE OF
BURNER
NOZZLE
RATED
THERMAL
FLOW RATE
kW
RATED
CONSUMPTION
REDUCED
HEAT
CAPACITY
kW
GAS PRESSURE
mbar
min. rat. max.
3.00
1.75
1.00
286 l/h
167 l/h
95 l/h
218 g/h
127 g/h
73 g/h
0.60
0.35
0.30
0.60
0.35
0.30
G20
20 mbar
1R - 2S -1A 7.50 715 l/h 9.52
G30
28-30 mbar
1R - 2S -1A 7.50 545 g/h 30.94
Type of gas used
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
CATEGORY II2H3+
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Rapid
Semi-Rapid
Auxiliary
214 g/h
125 g/h
71 g/h
0.60
0.35
0.30
25
37 45
20
35
G31
37 mbar
1R - 2S -1A 7.50 535 g/h 23.80
85
63
50
3.00
1.75
1.00
3.00
1.75
1.00
Summary of Contents for PAA 642 /I(WH)