Service Manual
Yate Production Dryers
Edition
2006.09.21
f not OK, replace the pump.
- Clean and refi t.
- Change the wiring.
- Replace the main board.
Check resistance continuity of the
pump.
Check state of the connectors.
Check continuity and state of the
wiring.
No pump action
Pump not wired
Valid only for condenser models.
FAULT 11
STATE
INTERVENTION TO BE PERFO
RMED
CORRECTIVE ACTIONS
- f the machine starts, ok.
- Clean and refi t.
- Change the wiring.
- Replace the main board.
- Replace the display board.
Display board does not manage to communicate with
FAULT 12
STATE
INTERVENTION TO BE PERFO
RMED
CORRECTIVE ACTIONS
No communication be-
tween display board
and main board.
Unplug the machine, wait for 2 min-
utes, switch it ON and try it again.
Check state of the connectors.
Check continuity and state of the
wiring.
If the wires and connectors are ok.