
12
Command Syntax:
Function:
Explanation:
TEDIT
◊
n
◊
x.xxxx
◊
y.yyyy
Replace data point pair #
n
with a
new data pair
x.xxxx,y.yyyy
Will possibly re-number entries in the
table (X=Degrees, Y= Conv. Value)
TDELETE
◊
n
Delete data point pair #
n
from
the N.L. Conversion Table
Will re-number entries in the table
TLEARN
◊
yy.yyy
Add a learned a data point pair
to the Non-Linear Conversion
Table
Will possibly re-number entries in the
table (Learned Degrees, Y= Conv. Value)
TAPS
◊
nn
Set number of taps
n
= an integer from 2 to 100
DEGSEG
◊
n.nnnn
Set degrees per segment
n
= a floating-point number, 5 digits max,
average number of degrees between taps
NEUTRALS
◊
n
Set number of neutral taps
n
= an integer from 0 to 9
NSTART
◊
nn
Set neutral start tap number
n
= an integer, any valid tap number
RLYLT
◊
nn
Set low relay tap number
n
= an integer, any valid tap number
RLYHT
◊
nn
Set high relay tap number
n
= an integer, any valid tap number
SETTAP
◊
nn
Set present tap position
n
= an integer, any valid tap number
LDTAP
Load present tap pos. into memory
Must be done for SETTAP to take effect
DISPRL
◊
ON
Enables the display of “r” (raised)
and “L” (lowered) tap numbers
“
ON
” or “
OFF
” When enabled causes the
display to show “r” and “L” in function
modes 20 and 21 only
ANACAL
Enter analog calibration mode, the
1250 analog output will be forced
to Low / Mid / High signal output
Press the space bar to toggle between
Low / Mid / High analog output. Press the
enter key to stop calibration
LEDTEST
Turns on all display segments
Press the enter key to stop the LED test
RLYTEST
Turns on one relay at a time for
testing
Press the space bar to toggle between
Low relay and High relay. Press Enter to
Exit Test
INCAL
Self-calibrates the input circuitry Outputs “Pass” or “Fail” calibration result
DSPBL
◊
ON
Enables the display blanking
feature
“
ON
” or “
OFF
” When enabled causes the
display to go blank after 60 sec.
AUTO25
Enables the automatic reset after
an “FA25” error
“
ON
” or “
OFF
” When enabled, will
automatically return to normal run mode
after input signal returns to normal range
RESET25
Resets “FA25” Error
Manually resets the “FA25” error.
SERIAL
◊
n
Set serial RS-232
communication mode
0=Serial Disabled, 1=Data Logger Mode,
2=Polled Mode, 3=Sampled Mode,
4=Serial Command Mode, 5= Reserved,
6=RS485 Mode, 7=Remote Display Driver
PORT
◊
bbbb
◊
w
◊
p
◊
s
◊
a
Set comm. port settings: baud
rate, word length, parity, stop
bits, and address
b
=
2400, 4800, 9600, 14400, 19200, 28800,
38400, 57600, 76800 baud
w
=
7 or 8-bit word
p
=
n, E, O
s
=
1 or 2 stop bits
a
= 0 to 255
PROGDIS
Displays Status of program
disable input
0=Open
1=Closed
MENU
◊
1
Set the menu type
“1”
=
Numeric menu or
“2”
= Alpha-numeric menu
HELP
◊
(command)
Lists all available commands
All commands will be listed with syntax