background image

9

GUARD

FOOT PEDAL

RUBBER BOOT

START BUTTON

STS THERMOSTAT

CONTROL BOX

BLOWER HOUSING

HEATER TERMINALS

BASE PLATE

Fig. 9

FOOT PEDAL

ASSEMBLY

INCINERATOR

CHAMBER

CAMLOC LATCH

FOR ASHPAN

ASHPAN

ASHPAN 

INSERT

HEATER

INCINERATOR LID

SPRING

BLOWER WHEEL

BLOWER MOTOR

HINGED BOWL 

IN CLOSED 

POSITION

TOP WITH

STAINLESS STEEL

BOWL HALVES

ITS THERMOSTAT
(TS THERMOSTAT LOCATED
BELOW AND TO THE RIGHT
OF ITS THERMOSTAT.  Fig. 5

TIMER

SCREWS

ACCESS 

PANEL

HINGED BOWL IN

OPEN POSITION

TEMPERATURE

CONTROLLER

ASHPAN 

PANEL

VENT

For help with troubleshooting 

or to order parts, call

1-800-527-5551

-USA

From other countries,

call agent shown on front cover.

RELAY

If service is needed, see the data plate on 
the back of toilet.  Please note serial # 
and voltage of your toilet.

Summary of Contents for CF

Page 1: ...late on back of toilet WARNING Do not operate INCINOLET until you have read thoroughly and understand completely all instructions and safety rules contained in this manual Save this manual and review frequently for continuing safe operation and instructing possible third party users For questions or assistance call 1 800 527 5551 Models TR and WB 240 volts SN 41000 Models CF and WB 120 volts SN 57...

Page 2: ...g During incineration there is flame and high heat in the burn chamber It is safe to use INCINOLET during the cycle and safe to push the pedal while standing to drop waste into what is already burning To avoid burn hazard 1 Never depress foot pedal while seated on toilet 2 Do not remove ashpan until toilet has cooled completely 3 Young children must be supervised when they use INCINOLET 4 Do not i...

Page 3: ...elow lid when lid closes 3 After use face toilet step on foot pedal to open bowl and allow waste to drop into incineration chamber Ash is germ free and safe to handle when it has burned to a light color If ash is dark or burn is incomplete run an extra cycle to assure safe handling of ash Ash is not suitable to use as fertilizer or compost It should be disposed of in household trash in accordance ...

Page 4: ...nly into a 20 amp receptacle Fig 4 If the outlet you intend to use for the INCINOLET is not the proper type then change the receptacle You must have a circuit suitable for 20 amps headed by a 20 amp circuit breaker Do not attempt to defeat this safety feature by modifying the plug in any way Power cord is 4 feet long Extension cords should not be used with this appliance Preparing Vent Line Vent p...

Page 5: ...may use hardware cloth with 1 4 mesh To prevent back drafting use a 90 degree elbow turned down or a rain cap if vented vertically START UP PROCEDURE Once Incinolet is connected to vent line and plugged into a 20 amp receptacle on a 20 amp circuit of the appropriate voltage it s a good idea to run a test cycle using a cup of water poured into a bowl liner BACK VIEW SIDE VIEW 5 Center of vent colla...

Page 6: ...r comes back on the fan should start automatically if needed and run until unit is cool enough Heater does not come on until you push the button You can push foot pedal to check contents of ashpan then start a cycle if needed To Interrupt an Incineration Cycle In normal use it is never necessary to stop a cycle to add waste See How to Use page 3 However on rare occasions doing repairs etc you may ...

Page 7: ...LINER FOR EACH AND EVERY USE Liner protects the bowl and prevents urine from draining to the floor How to Remove Ashpan Remove ashpan only when pan is cool and toilet is not operating Removing the Top Seat Lid Bowl Halves Top is held in place with four screws two per side and a rubber boot which protects the start button Remove them and then lift top up To replace top With incinerator lid closed h...

Page 8: ...e red light A steady green light on timer indicates unit has power and is ready for operation When start button is pushed green light begins blinking and the red light comes on and stays on for a timed interval during which time temperature controller is activated and its red light is on Controller red light means that the relay is activated and supplying power to heater Controller red light stays...

Page 9: ...IN CLOSED POSITION TOP WITH STAINLESS STEEL BOWL HALVES ITS THERMOSTAT TS THERMOSTAT LOCATED BELOW AND TO THE RIGHT OF ITS THERMOSTAT Fig 5 TIMER SCREWS ACCESS PANEL HINGED BOWL IN OPEN POSITION TEMPERATURE CONTROLLER ASHPAN PANEL VENT For help with troubleshooting or to order parts call 1 800 527 5551 USA From other countries call agent shown on front cover RELAY If service is needed see the data...

Page 10: ...e above procedure Locate heater in brackets making sure brackets are seated in slots in the incinerator wall Fig 11 2 IMPORTANT Locate heater at lowest position in heater bracket Coils must not touch each other Replace insulation and cover over heater terminals Fig 11 1 Replace thermocouple Push knurled cylinder to compress spring Turn to engage stud then release Spring must be compressed to insur...

Page 11: ...t is clean clean the catalyst To do this open catalyst container by removing two nuts and cover plate Use a small hand held vacuum to pull out pellets SAVE PELLETS Gently rolling pellets in a flat pan facilitates removal of dust Brush chamber walls to clean perforations Put cleaned pellets back and attach cover Catalytic action should now be fully effective Thermocouple Thermocouple in combination...

Page 12: ...Revised 08 18 W4 G6 E Y R F P7 E5CS 5 Yellow Y Y R 02 B3 BLOWER RELAY 44 ...