Specifications Summary
All installations must be in accordance with state and local codes.
WASTE CHAMBER
Chamber capacity
(Type IV waste - animals)
200 kg
Chamber volume
.36 m
3
Width 91
cm
Height 86
cm
Chamber size
(outside)
(less burner and
counter weights) Length 122
cm
Door opening
56 x 74 cm
Height to door
77 cm
Height to top of stack
3.3 m
Suggested slab size
(L x W x Thickness)
1.8 m x 2.4 m x 10 cm
STACK
30 cm diameter 16 gauge (1.52 mm) stainless steel
BURNERS
LP or natural gas burner.
Oil burner
Operation
Single burner or Two stage burn with timer (Defra models only)
Standard - 115 volt, 60 HZ, 20 amp
ELECTRICAL SERVICE
Also available - 220 volt, 50 HZ, 10 amp
LP
3.0 GPH
11.4 l/hr
Natural
275 CFH
7.8 m
3
/hr
FUEL
CONSUMPTION
Fuel Oil
3.0 GPH
13.2 l/hr
Secondary Chamber (DEFRA Approved models only)
Chamber size (outside)
Width 43cm
Height 200cm
Length 66cm
Chamber Volume
.44 cubic meters
We reserve the right to alter specifications without prior notice
Installation
Must be installed in accordance with local codes and ordinances, subject to regulatory
agencies. Stack test data is available from the distributor for permit application. If on-site
testing is required, it is the responsibility of the purchaser and can be arranged through the
distributor. Outside installation is recommended with a simple metal roof or three-sided
metal shelter, providing a minimum four foot clearance from any combustible material.
Inside installations may have special insurance requirements. Factory must be advised.