12In models of super crushing with the end of two screw drivers make prise
in the inferior extreme of the bronze ring.
18. Put lubricant and put the steel washer.
19. After substituting the O-ring in the rusher ice machine, install it in the
inner side of the axis and fix it to the upper nut.
20. Install the axis/crusher ice equipment in the evaporator following the
above instruction on the other way round.
J. SUBSTITUTION MOTOR OF THE REDUCTION GEAR
1 Take out the frontal/upper panel and back/side panel in models MF22,
MF30, MF41 and MF51 and in model MF61 the frontal panel and the left
upper panel.
2. Unscrew the ¾ nuts that fix the evaporator in the upper body of the
reduction gear.
3. Take out the sensor of rotation direction following instructions in section E,
unscrew the screws that fix the motor of the reduction gear in the framwork.
4. Disconnect the motor of the electrtical conexión of the unit. The reduction
gear now can be substituted.
5 To install the new motor of the reduction gear follows the instructions on the
other way round.
NOTE. It is recommended to substitute the mechanic retention ring, the
ball bearing upper and inferior as well as the bindings or every time the
evaporator is dismantled. There is one kit with these spare parts
number 001028.07 for MF22-30 and number 001028.08 for MF41-51-61
with a fat tube and water repellent.
13. From the interior of aluminium support, take out the components that
integrate the transmision connection.
14. Check the two half-connections, if they are not in good conditions replace
them.
15. Install the inferior ball bearing in its bronze place taking attention with the
plastic ring.
16 Install the upper ball bearing in the crush ice equipment starting from the
radial side that has to be installed with the flat side.
17. Put lubricant in the upper side, and install the ball bearing box with the
small holes upwards to give a free movement between the plastic box and
the flat area of the inner side of ball bearing (check picture).
NOTE. Drain carefully the cooking circuit to remove excess of humidity and
the condensation gas after substituting the condenser..
K. SUBSTITUTION OF WATER CONDENSER
1. Take out hte frontal/upper panel and side/upper panel in models MF22,
MF30, MF41 and MF51 and the frontal/right side panel in model MF61
2. Take from the condenser the sensitive bulb of the sensor.
17
Summary of Contents for MF 22
Page 1: ......
Page 21: ...ELECTRICAL DIAGRAM MF 22 30 COOLED WITH AIR AND WATER 19 ...