TROUBLESHOOTING
PROBLEM
CAUSE
MEASURE TO TAKE
Room temperature too high
Install unit in a more fresh room
Temperature
Enough or two much quantity Control the refrigerant
Of regriferant
Ice very
Water tank level too high
Low the tank or the level of water
Ineficient compresor
Sustitute the compresor
Axis profile wear away
Sustitute the axis
Water doesn’t enter into
Tubo de alimentación de agua al
The evaporator
evaporador obstruido. Desatascar el
Tubo de alimentación. Limpiar
The unit works
But it doesn’t produce ice Gear teeths of the reductor
Substitute the gear teeths
Wear away
Humidity in the system
Discharge and charge
Broken water seal
substitue
Supply pipe to the evaporator Check the brackets
Damage or free
Lose of water
Float valve doesn’t close
Adjust the screw of the float
Joint broken in the outlet
Substitute the joint in the outlet
discharge
discharge
PROBLEM
CAUSE
MEASURE TO TAKE
Lime deposit or minerals in the interior Unistall axis and clean it with emeril felt
Of the evaporator or axis
Clean the inner surface of the
Evaporator brushing vertically
Aspiration pressure to low
Add refrigerant
Water pipe supply to the
Check and clean.
Noise and excessive creak Evaporator partially obstruct
Water level tank too low
Raise the level
Ball bearing in the evaporator
Check and substitue
broken
Ball bearing in the motor
Check and substitue
Wear out
Not enough lubricant in the reduction Check lose of lubricant, substitute the
Noisy reduction motor
motor
Sels and add lubricant
MOBILPREX IP 44
Ball bearing or gear teeth of the
Check and substitue
Reduction motor seize up
Inlet water filter obstructed
Clean the filter
Nozzle of the water tank obstructed Clean the nozzles after taking out
Lack of water
The float
Water supply pipe
Check and substitue
From the evaporator partially
obstruct
22