background image

23

24

SELECTING A HEAL

THCARE PR

OGRAM

V

OICE CONTR

OL OPERA

TION GUIDE

4 to 8 inches

Microphone

SELECTING A HEALTHCARE PROGRAM

2

Adjust the lower arm 
units to the desired 
position. 

1

Press the [POWER] button.

If a Healthcare Program is not 
selected within 5 minutes, the power 
will automatically shut off.

You are asked to select the program.

3

Select your favorite 
Healthcare button. 

Display shows chosen Healthcare Program.

* Now, Shiatsu Point Locator Function will start. Wait for a moment.

See page 14 for details. 

4

Now, you can adjust the Shoulder Position.

Use the Shoulder Position Adjustment buttons to raise or lower the roller 
position. If no adjustment is necessary, just wait for program to start.

5

Place your arms into 
the lower arm units.

Massage has completed.

6

Air massage of legs and arms starts.

7

When massage action is complete, the rollers return to 
Storage Position (upper part of the seat back).

Arm air massage starts a moment after the pro-
gram starts.

* Take off hard objects like watches, bracelets, or rings beforehand. 

Always sit as far back as possible and place your head on the 
pillow for precise Shiatsu Point.

 Keep a massage session to no more than 15 minutes in length and Area-Specific Massage of 

any particular area on the body to no more than 5 minutes.

 

Continual use for extended periods of time can result in over-stimulation, which could cause the 

opposite of the desired effect, or even injury.

Aim for no more than 30 minutes total massage time per day.

Caution

Voice Control Unfriendly Condition

Microphone Position

 TV or AV equipment set nearby is too loud.

 Conversation or noise nearby is too loud.

Pages 24 to 28 give instructions on the voice control function.

VOICE CONTROL OPERATION GUIDE

      mark can be found alongside several items in this manual.
You can operate these items with voice control ON.

In some cases, voice control may fail to function since it has difficulty in identifying 
voiced keywords under such circumstances. Do not take this as a failure of the 
product. If this unit is needed to operate in such an environment, use the remote 
control instead.

Voice control (registration/operation) may not work properly depending on the 
environment. For example:

Mark

Voice

Voice

Keep the microphone 4 to 8 
inches away from your mouth 
when using (See the 
illustration to the left). It is 
difficult to recognize voiced 
keywords in the event that the 
microphone is too close or 
too far.

Summary of Contents for HCP-D5A

Page 1: ...imes minute to maximum 650 times minute Tapping Speed Roller Width 3 levels Narrow Medium and Wide Vertical Speed Approx 20 seconds lap Back Stroke Range Approx 25 inches in partial roller massage pro...

Page 2: ...nd even the smallest tear Unplug the chair and contact the vendor for assistance Prohibited Do not disassemble Do not touch Required action Unplug the chair Electrical grounding Warning or caution Do...

Page 3: ...during leg or foot massage do not try to force it back in Undue force on the chair may damage the unit If your arm comes out of the lower arm units during lower arm massage do not try to force it back...

Page 4: ...nnector Plug Wheels Remote Control Seat Armrest Foot Unit Control Box Reclining Safety Mechanism Remote Control Stand Microphone Attachment Unit Microphone Speaker Power Connector Main POWER Switch Fo...

Page 5: ...a section during operation of a health care program Vibration Cancel Buttons Use to cancel vibration during operation of a healthcare program Volume Button Panel See next page for illustration of ope...

Page 6: ...of high humidity like bathrooms or saunas Only install on a flat level surface Do not use in areas of high debris or dust content Do not use where the ambient temperature is 100 F or more Do not insta...

Page 7: ...s upright position if the reclining button is not released To lower the seat back Press the DOWN button Release when your desired angle is obtained The seat back will end up in the chair s horizontal...

Page 8: ...s unit large and small These 2 headrests help to stabilize your head in a natural and comfortable position during the massage The smaller headrest s position can be adjusted with the Velcro at the bac...

Page 9: ...FEATURES MASSAGE PROGRAMS SELECTION Voice Control Mode only Voice This massage with a variety of movements is provided through the voice operation function Reproduce your favorite settings by accepti...

Page 10: ...Full 3D Full Stop by pressing the button Can be switched between 2D Partial 3D Partial Stop by pressing the button Up Down Front Back movements to partially extend spine Up Down movement only to parti...

Page 11: ...ers return to the storage position upper part of the seat back Massage action continues for 15 minutes Massage has been completed Caution Guide To Combining Adjusting Manual Selection Massages This gu...

Page 12: ...utton during a Healthcare Program rollers once return to Storage Position to restart with Automatic Shiatsu Point Locator Function Stopping In The Middle Of Massage To stop in the middle of a massage...

Page 13: ...ise Shiatsu Point Keep a massage session to no more than 15 minutes in length and Area Specific Massage of any particular area on the body to no more than 5 minutes Continual use for extended periods...

Page 14: ...rent number button for registration 6 Voice registration is completed The voice registration is complete The present voice setting is memorized in No 1 or No 2 or No 3 or No 4 If voice registration wa...

Page 15: ...conds Say repeatedly until the desired angle is obtained Extend the footrest for 0 5 seconds Say repeatedly until the desired length is obtained Retracts the footrest for 0 5 seconds Say repeatedly un...

Page 16: ...eakage Just slightly lift your body The rollers are designed to provide for the alternating tap ping function so in the stopped position they are some times out of line this is part of their design an...

Page 17: ...appropriate button with your registered voice Re register your voice if any one of following cases is applicable Have you used different intonation for keywords in operation from that of initial regi...

Page 18: ...will be charged for repairs even while the chair is under warranty 1 WARRANTY 2 REPAIRS SERVICE Regular Maintenance Will Preserve the Life of Your Chair The chair does not start with the main power sw...

Reviews: