background image

Exago 

Manual

Exago 

Manual

19

www.imv-imaging.com

 |

An icon in the upper right part of the 

screen indicates the battery level. When 

battery goes down to 20% and 10%, low 

battery warning appears.

 

The icon in the lower right part of the 

screen indicates either the internal me

-

mory (marked Exago) or on a connected 

USB. If the indicator is red, the memory is 

full. 

During storage of images or clips, the fo

-

llowing icons are displayed on the screen 

according to a storage media:

A downward 

arrow indicates a 

storage on the internal Exago 

memory. 

An upward

 arrow indicates 

storage on a USB stick. 

An arrow facing the right 

indicates storage of the Dicom 

server.

14. Screen icons

Summary of Contents for EXAGO

Page 1: ...1 www imv imaging com Your complete animal imaging solution Instruction manual...

Page 2: ...mode and menu 8 5 CFM mode and menu 9 6 PW mode and menu 9 7 Measure menu 8 Review menu 9 Probe menu 10 Settings 11 Protocol menu 12 Report menu 13 Patient menu 14 Screen icons 15 Cleaning and disinfe...

Page 3: ...ned for the following atmospheric pressures 700 hPa to 1060 hPa while in operation 500 hPa to 1060 hPa during transporta tion and storing 1 3 Electrical safety This equipment is compliant with IEC sta...

Page 4: ...aintenance reasons never disconnect a probe from the device without freezing the system first All probes provided with the Exago device are compliant with the standard ISO 10993 1 concerning biocompat...

Page 5: ...robe connected on the connector 2 2 Use of Exago trolley If the equipment is used with the Exago trolley check that a probe is connected to the right hand side connector 2 3 Starting of the device To...

Page 6: ...Line adjustment In Freeze mode move to previous Cineloop image Current image index is displayed on screen Measure menu Touchpad used for menu selection mea surement cursors validation of measure ments...

Page 7: ...indow positioning adjustment Exit Noise Rejector Biopsy Power Dynamic Dynamic Range of B image Transmit Power Adjust Brightness Brightness Dual L R U D Frame Average Noise Reject Compare two images in...

Page 8: ...ch from Active CFM mode to Pre trace CFM mode Power CFM transmit Power Rejection of movements from vessel walls and tissues High Wall Filter slow speeds are rejected Wall Filter Persistence Frame aver...

Page 9: ...e trace or PW mode Press Update to switch from Active PW mode to Pre trace PW mode When PW is activated from CFM mode the Update key allows to come back to CFM mode with the gate active Select Gate Si...

Page 10: ...settings of the menu Use Touchpad to adjust caliper posi tioning and validation Terminate the measurement Draw Trace countour Distance Four distances can be acquired on the same image Choose distan ce...

Page 11: ...EVIEW CFM B SELECT DEPTH GAIN DEPTH GAIN FREEZE UPDATE STORE Access Review menu for reviewing images and clips Keys to change settings of the contex tual menu Use Touchpad to select file or clip Exit...

Page 12: ...DEPTH GAIN FREEZE UPDATE STORE Keys to change settings of the contex tual menu If no contexual keys used for 15 seconds the system exits the probe menu Probe 2 Only active if the device is used on du...

Page 13: ...red with the Text button on the keyboard automati cally when pressing Text Select image format Dicom only allows to save the images only in this format Enter user patient informaton Select language Ch...

Page 14: ...nsfer to DICOM server is imme diate when pressing store When not ticked the DICOM images can be saved in a Patient Report in DICOM for mat Enter Patient ID if DICOM storage is used Information about n...

Page 15: ...ata table in data or graphical mode Next Previous controls are used to review table of different authors Dicom folder Print menu Print server Application Entity name Allocated by the network administr...

Page 16: ...image and return the previous caliper for adjustment Freeze the image and use Cursor to scroll the protocol list Scroll the protocol menu using Tou chpad Validate the first caliper and activate the se...

Page 17: ...ange settings of the menu Exit the menu return to current exami nations or see images and clips Page 1 Export USB Export selected data to external USB device Move to the next report image Display sele...

Page 18: ...ARROW PATIENT REPORT PROTOCOL PROBE ZOOM TGC SETTINGS CLEAR FREQUENCY FOCUS M CINELOOP PWD MEASURE REVIEW CFM B SELECT DEPTH GAIN DEPTH GAIN FREEZE UPDATE STORE Keys to change settings of the menu Cli...

Page 19: ...creen indicates either the internal me mory marked Exago or on a connected USB If the indicator is red the memory is full During storage of images or clips the fo llowing icons are displayed on the sc...

Page 20: ...in a solution of mild soap and water Switch off and disconnect the device together with all connected peripherals 4 Remove any cleaning solution residue with a clean soft cloth damped in sterile water...

Page 21: ...he system 3 Wipe the probe and cable with a clean soft cloth that has been dam ped in a solution of mild soap and water 4 Remove any cleaning solution residue with a soft clean cloth damped in sterile...

Page 22: ...aedics tendons small parts Convex C360 A B mode 2 5 to 5 0 MHz 128 Abdominal for large small animals Convex C320 A B mode 2 0 to 5 0 MHz 128 Abdominal and cardiac especially for small animals Micro co...

Page 23: ...100 240 V 47 63 Hz Out Put 120 W Max 19V Inputs and Outputs RJ 45 Video Out For external screen and thermal printer DVI connection USB port Processing 32 true emission channels 64 reception channels M...

Page 24: ...ork loin marbling This software works with the Exago and its large probe 13 cm probe www biotronics inc com ECOTEXT Testicular analysis software for all species Developed by Humeco ECOTEXT is a comput...

Page 25: ...imaging com www imv imaging ie United Kingdom HQ IMV imaging Imaging House Phoenix Crescent Strathclyde Business Park Bellshill ML4 3NJ Scotland UK 44 0 1506 460 023 info imv imaging com www imv imag...

Page 26: ...facebook com IMVimaging twitter IMVimaging www imv imaging com info imv imaging com 44 0 1506 460023 Contact us now IMV imaging V 13 August 2019 Instruction manual ExaGo Instruction manual...

Reviews: