www.imv-imaging.com |
17
Checking the cervix
1. Clean the animal’s vulva using the same
protocol as with a standard insemination.
2. Put B-LUBE gel on the end of the speculum
over approximately the first 10cm.
3. Part the vulva. Position the end of the
speculum against the vulva. Point the
camera upwards at a 45º angle.
4. Gently insert the speculum, aligning it
parallel to the vagina.
Operating
instructions
5. Once it is 10cm inside the vagina pull back
on the sanitary sheath to open it at the front.
6. Progress towards the cervix using the
image displayed on your viewing device to
navigate.
7. Check the condition of the cow’s cervix on
the image
Now you should be able to make a diagnosis
or a decision on insemination. If insemination,
proceed with the next steps.