![IMS MDrive 34 Plus Series Hardware Reference Manual Download Page 55](http://html.mh-extra.com/html/ims/mdrive-34-plus-series/mdrive-34-plus-series_hardware-reference-manual_2049848055.webp)
A-5
Appendices
Recommended IMS Power Supplies
IMS unregulated linear and unregulated switching power supplies are the best fit for IMS drive products.
IP804 Unregulated Linear Supply
Input Range
120 VAC Versions ...........................................................................................102-132 VAC
240 VAC Versions ...........................................................................................204-264 VAC
Output (All Measurements were taken at 25˚C, 120 VAC, 60 Hz)
No Load Output Voltage ........................................................................76 VDC @ 0 Amps
Half Load Output ..................................................................................65 VDC @ 2 Amps
Full Load output ....................................................................................58 VDC @ 4 Amps
IP806 Unregulated Linear Supply
Input Range
120 VAC Versions ...........................................................................................102-132 VAC
240 VAC Versions ...........................................................................................204-264 VAC
Output (All Measurements were taken at 25˚C, 120 VAC, 60 Hz)
No Load Output Voltage ........................................................................76 VDC @ 0 Amps
Half Load Output ..................................................................................68 VDC @ 3 Amps
Full Load Output ...................................................................................64 VDC @ 6 Amps
ISP300-7 Unregulated Switching Supply
Input Range
120 VAC Versions ...........................................................................................102-132 VAC
240 VAC Versions ...........................................................................................204-264 VAC
Output (All Measurements were taken at 25˚C, 120 VAC, 60 Hz)
No Load Output Voltage ........................................................................68 VDC @ 0 Amps
Continuous Output Rating ....................................................................63 VDC @ 2 Amps
Peak Output Rating ...............................................................................59 VDC @ 4 Amps
Recommended Power Supply Cabling
MDrivePlus Supply Cable AWG Table
3 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Minimun AWG
18
16
14
12
12
4 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Minimun AWG
18
16
14
12
12
*Use the alternative methods illustrated in examples B
and C when cable length is ≥ 50 feet. Also, use the same
current rating when the alternate AC power is used.
Table B.1: Recommended Supply Cables
Summary of Contents for MDrive 34 Plus Series
Page 12: ...1 6 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Page 24: ...1 18 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Page 26: ...2 2 MDrive34Plus Motion Control Hardware Revision R080106 ...
Page 50: ...2 26 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...