Sourcing Output
Application Example
This application example will illustrate two MDrivePlus2 units in a system. In the program example
MDrivePlus2 #1 will be configured as a Fault Output, which when HIGH will trip an input on MDrivePlus2
#2 which will be configured as a Pause Input.
MDrive #1
S9=18,1,1 ‘Configure IO9 as a Fault output, active HIGH, sourcing
MDrive #2
S9=6,1,1 ‘Configure IO9 as a Pause Input, active HIGH, sourcing.
Internal
pull-up
voltage
The internal pull-up voltage
cannot provide output
current / voltage
24.9k ohms
Sourcing Output Equivalent Circuit
always
off
switched
IOPWR
IOx
IOGND
MDrivePlus
2
load current, sourcing
Sourcing Output
Sourcing Input
cuit
g Input Equivalent Circ
urcin
Sou
n
c
u
Internal
pull-up
voltage
detect
logic
40 - 135 uA
24.9k ohms
100k ohms
3.3 V
The internal pull-up voltage
cannot provide output
current / voltage
IOPWR
IOx
IOGND
Iih
MDrivePlus
2
#2
MDrivePlus
2
#1