![Improved Racing EFR-100 Instructions Manual Download Page 10](http://html.mh-extra.com/html/improved-racing/efr-100/efr-100_instructions-manual_2049711010.webp)
For contact information, visit www.improvedracing.com
10
HRG-1019
HRG-1018
Figure 6 -
HRG-1018 and HRG-1019 O-Ring Placement
6.
Use a 6 mm hex tool and the HSC-1058 mounting screws to secure
EFR-100 to the engine block.
Do not pinch or damage the O-rings.
7. Torque all HSC-1058 screws to 25 lb-ft (33 N-m).
8. Install the lower radiator hose and clamps.
Consult the Installation Notes on Page 2 and Page 3 for vehicle specific
fitment and parts.
EFR-800 HOSE MODIFICATION FOR 1996-2004
MUSTANG SVT COBRA & MACH 1 TRIMS
1.
Install the correctly cut hose onto the barb fitting of EFR-100.
2. Insert the reducer into the cut end of the hose and secure to the inline
thermostat with the included worm clamp.
3.
Use a 7mm (9/32”) tool to secure the hose onto the barb using the pro
-
vided worm clamp.
INSTALLING THE REMOTE OIL FILTER MOUNT
1.
Secure the remote oil filter mount to the vehicle.
2.
Plan, measure, cut, and assemble the oil system lines.
3.
Connect the oil lines to the EFR-100 and the remote oil filter mount.