MODEL NUMBER:
IXP904-1-0-GB-XX
IXP905-1-0-GB-XX
IXP906-1-0-GB-XX
XEA901-1-0-GB-XX
XEA902-1-0-GB-XX
xea
IXP110 C
ONTROLLER
ImproX IXP110 Controller
INSTALLATION MANUAL
SPECIFICATIONS
Working Environment
.................
Designed to work in an indoor (dry)
environment similar to IP40. The Controllers
are NOT sealed against water.
Power Requirements
Input Voltage using a Sealed
Lead Acid Backup Battery,
Connected to the Battery Input
and or Strike Lock Connected
to the Power Output ...............
14 V AC to 18 V AC.
18 V DC to 24 V DC.
Input Voltage NOT using a
Sealed Lead Acid Backup
Battery and or Strike Lock ......
9 V AC to 18 V AC.
9 V DC to 24 V DC.
NOTE:
Battery Charging Voltage and
Power Output Voltage are set at
between 13.6 V DC and 13.8 V DC.
NOTE:
This current is measured using
18 V DC Input Voltage.
IXP110 with two Antenna
Readers Connected ...............
135 mA (2.43 W).
NOTE:
Each Relay draws an extra
120 mA.
NOTE:
The IXP110 current limits the
charging current into the Sealed
Lead Acid Battery to a maximum of
350 mA.
NOTE:
The maximum size Sealed Lead
Acid Battery that can connect to the
Battery Input is 12 V, 7 Ahr.
NOTE:
The maximum current that can be
drawn from the Power Output is
250 mA. (If using a Maglock or
high current Strike Lock, connect
the Lock to a separate power
supply).